EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY-NC 4.0

Transvenous Lead Extraction Versus Abandonment of non‐Infected, Superfluous Leads—A Meta‐Analysis and Systematic Review

Karanjeet Chauhan iD, Philip Jakanovski, Thalys Sampaio Rodrigues iD, Marwan Shawki, Nicholas Sclavos, Louise Segan iD, Neil Strathmore, Alistair Royse, Gareth Wynn iD

Pacing and Clinical Electrophysiology · 15.07.2026

DOI: 10.1111/pace.70356 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 15.07.2026. Verfasst von Karanjeet Chauhan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Royal Melbourne Hospital, Parkville, Victoria, Australia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Managing non‐functional cardiac implantable electronic device (CIED) leads remains controversial. While extraction is standard for infection, it is unclear whether transvenous lead extraction (TLE) or lead abandonment (LA) provides superior outcomes for superfluous leads. Prophylactic TLE may prevent future infection or venous obstruction and avoid complex delayed extraction but carries immediate procedural risk. Conversely, LA avoids upfront risk, though retained leads may predispose to long‐term sequelae.

Objectives

To compare procedural and clinical outcomes of TLE versus LA for non‐infected leads and assess how pre‐existing abandoned leads influence the risks of subsequent extraction.

Methods

PubMed, Embase, OVID, and Cochrane were searched (2000–2025) for studies comparing TLE versus LA and TLE with versus without abandoned leads. Twenty‐three observational studies involving 65,760 patients were included. Data was extracted by two investigators using PRISMA guidelines. Primary outcomes included major complications, in‐hospital mortality, and clinical success, pooled as odds ratios with 95% confidence intervals using a random‐effects model. Subgroup and meta‐regression analyses were performed.

Results

TLE was associated with significantly higher odds of major complications (OR 2.07, 95% CI 1.42–3.03) and in‐hospital mortality (OR 2.97, 95% CI 1.95–4.53) compared with LA, with no significant long‐term difference within limited follow‐up. Extraction of previously abandoned leads carried higher risks of major complications (OR 2.51), minor complications (OR 1.79), and mortality (OR 2.06), with lower clinical success (OR 0.24) than functional leads. Recent studies show improved TLE safety.

Conclusion

While TLE carried higher immediate risks, measured long‐term outcomes were comparable; however, follow‐up was insufficient to capture late abandonment‐related sequelae. Extraction of previously abandoned leads carried markedly higher risk, supporting earlier extraction in appropriately selected patients.

Schlagwörter

Stichwörter der Autor:innen

abandoned leadscomplicationselectrophysiologyimplantable defibrillatorlead extractionpacemaker

Autor:innen und Institutionen

  • Department of Cardiology, Royal Melbourne Hospital, Parkville, Victoria, Australia.
  • Department of Medicine, University of Melbourne, Parkville, Victoria, Australia.
  • Department of Medicine, Monash University, Clayton, Victoria, Australia.
  • Department of Cardiology, Austin Health, Heidelberg, Victoria, Australia.
  • Department of Cardiology, Latrobe Regional Health, Traralgon, Victoria, Australia.

ORCID-Profile: Karanjeet Chauhan, Thalys Sampaio Rodrigues, Louise Segan, Gareth Wynn

Zitieren

APA

Chauhan, K., Jakanovski, P., Rodrigues, T. S., Shawki, M., Sclavos, N., Segan, L., Strathmore, N., Royse, A., & Wynn, G. (2026). Transvenous Lead Extraction Versus Abandonment of non‐Infected, Superfluous Leads—A Meta‐Analysis and Systematic Review. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70356

Vancouver

Chauhan K, Jakanovski P, Rodrigues TS, Shawki M, Sclavos N, Segan L, et al. Transvenous Lead Extraction Versus Abandonment of non‐Infected, Superfluous Leads—A Meta‐Analysis and Systematic Review. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70356

BibTeX
@article{Chauhan2026,
  author = {Chauhan, Karanjeet and Jakanovski, Philip and Rodrigues, Thalys Sampaio and Shawki, Marwan and Sclavos, Nicholas and Segan, Louise and Strathmore, Neil and Royse, Alistair and Wynn, Gareth},
  title = {Transvenous Lead Extraction Versus Abandonment of non‐Infected, Superfluous Leads—A Meta‐Analysis and Systematic Review},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70356}
}
Kostenlos starten →