EUVIMEDAtrasti EUVIMED
Open access · CC BY 4.0

Predicting Major Adverse Events With Cardiac Resynchronization, Leadless, and Conduction System Pacemaker Implantation

Samuel W. Reinhardt, Yongfei Wang, Omar Aldaas, Maria Camila Trejo Paredes, Karl E. Minges, Kimberly Marshall, Beth Denton, Sarah Zimmerman, Jonathan C. Hsu, James V. Freeman

Pacing and Clinical Electrophysiology · 2026-11-22

DOI: 10.1111/pace.70461 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, published online on 2026-11-22. Written by Samuel W. Reinhardt and 9 co-authors. 14 references. The full text is freely available (open access, CC BY 4.0).

SantraukaBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Background

Large‐scale contemporary risk prediction models for adverse events after pacemaker implantation are lacking. The National Cardiovascular Data Registry EP Device Implant Registry has collected data on pacemaker implantations including cardiac resynchronization therapy pacemakers (CRT‐P), leadless pacemakers, and His/left bundle pacemakers since April 2021.

Objectives

To produce a standardized risk model for in‐hospital complications following CRT‐P, leadless, and His/left bundle pacemaker procedures.

Methods

Data from 21,211 novel pacemaker procedures across 179 hospitals from January 2022 to June 2024 were used to develop and validate a model to predict in‐hospital complications.

Results

The overall in‐hospital complication rate was 2.00% (range 1.69%–2.23% and interquartile range 1.98%–2.01%), which varied somewhat by device type: CRT‐P 1.76%, leadless pacemaker 2.51%, and His/left bundle pacemaker 1.85%, p = 0.0052. Prior MI, prior cardiac arrest, sodium >145 mEq/L, and being hospitalized for cardiac or non‐cardiac reasons not related to the procedure were the most significant risk factors for complications. The model demonstrated moderate discrimination with a C‐index of 0.714 for the total cohort; this varied somewhat but showed helpful discrimination for each device‐type (C‐index of 0.716 for CRT‐P, 0.795 for leadless pacemakers, and 0.663 for His/left bundle pacemakers).

Conclusions

We developed a risk model for CRT‐P, leadless, and conduction system pacemakers with overall helpful risk prediction, although it varied by device type. Modifications to the EPDI Registry data collection form and larger numbers of procedures in the registry over time will allow for separate, device‐specific risk models in the future that may offer improved performance.

Cite

APA

Reinhardt, S. W., Wang, Y., Aldaas, O., Paredes, M. C. T., Minges, K. E., Marshall, K., Denton, B., Zimmerman, S., Hsu, J. C., & Freeman, J. V. (2026). Predicting Major Adverse Events With Cardiac Resynchronization, Leadless, and Conduction System Pacemaker Implantation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70461

Vancouver

Reinhardt SW, Wang Y, Aldaas O, Paredes MCT, Minges KE, Marshall K, et al. Predicting Major Adverse Events With Cardiac Resynchronization, Leadless, and Conduction System Pacemaker Implantation. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70461

BibTeX
@article{Reinhardt2026,
  author = {Reinhardt, Samuel W. and Wang, Yongfei and Aldaas, Omar and Paredes, Maria Camila Trejo and Minges, Karl E. and Marshall, Kimberly and Denton, Beth and Zimmerman, Sarah and Hsu, Jonathan C. and Freeman, James V.},
  title = {Predicting Major Adverse Events With Cardiac Resynchronization, Leadless, and Conduction System Pacemaker Implantation},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70461}
}
Start for free →