EUVIMEDObjevte EUVIMED
Crossref

Efficacy, Safety, and Procedural Outcomes of Pulsed‐Field Ablation for Paroxysmal Atrial Fibrillation: A Meta‐Analysis

Mohamad Anas Oudih iD, Marco Schiavone iD, Mouaz Oudih iD, Muhammad Khuzzaim Khan iD, Majd Al Deen Alhuarrat iD, Hussam Al Hennawi iD, Nils Guttenplan iD, Fengwei Zou, Daniel Pugliese, Luigi Di Biase, other members of the PFA Meta‐Analysis Study Group

Pacing and Clinical Electrophysiology · 2026-07-25

DOI: 10.1111/pace.70375 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, published online on 2026-07-25. Written by Mohamad Anas Oudih and 10 co-authors. Institution: Division of Internal Medicine, Ball Memorial Hospital, Indiana University, Muncie, Indiana, USA. 57 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Introduction

Pulsed‐field ablation (PFA) is a novel, nonthermal modality for the treatment of atrial fibrillation (AF) that may reduce procedural complications compared with conventional thermal ablation methods. Methods and Results A systematic literature review was conducted to identify studies comparing PFA with second‐generation cryoballoon ablation (2G‐CBA) and contact force‐sensing radiofrequency ablation (CF‐RFA) for paroxysmal AF (pAF) from the inception of PFA to January 2026. A single‐arm meta‐analysis was performed using random‐effects models, reporting the arcsine of the square root transformation (PAS) or mean (95% CI) for each intervention. Overall, 29 studies (9 randomized controlled trials and 20 observational studies) were included. Arrhythmia recurrence rates were comparable across all three interventions [PFA: 23.90% (PAS 0.24, 95% CI 0.19–0.29, p < 0.0001); CF‐RFA: 23.72% (PAS 0.24, 95% CI 0.19–0.29, p < 0.0001); 2G‐CBA: 25.56% (PAS 0.26, 95% CI 0.20–0.31, p < 0.001)]. Overall procedure time was significantly shorter with PFA than with CF‐RFA and comparable to 2G‐CBA [PFA: mean 87.66 min (95% CI 74.29–101.04, p < 0.001); CF‐RFA: mean 137.54 min (95% CI 123.65–151.43, p < 0.001); 2G‐CBA: mean 105.56 min (95% CI 89.93–121.18, p < 0.001)]. Fluoroscopy time was shorter with PFA than with 2G‐CBA but comparable to CF‐RFA [PFA: mean 16.12 min (95% CI 12.36–19.88); CF‐RFA: mean 17.28 min (95% CI 13.59–20.98); 2G‐CBA: mean 22.08 min (95% CI 18.23–25.94)]. Overall complication rates did not differ significantly among the three interventions [PFA: 2.93% (95% CI 1.87–4.22%); CF‐RFA: 3.66% (95% CI 1.84–6.07%); 2G‐CBA: 6.52% (95% CI 4.41–9.00%)]. The incidence of phrenic nerve palsy was significantly higher with 2G‐CBA than with PFA or CF‐RFA.

Conclusion

PFA demonstrated comparable efficacy and safety to CF‐RFA and 2G‐CBA, with a numerically shorter procedure time than CF‐RFA and a lower incidence of phrenic nerve palsy than 2G‐CBA, supporting PFA as a viable alternative to established ablation techniques for pAF.

Subjects

Author keywords

arrhythmiaatrial fibrillationcryoballoon ablationparoxysmal atrial fibrillationpulmonary vein isolationpulsed‐field ablationradiofrequency ablation

Authors and institutions

  • Division of Internal Medicine, Ball Memorial Hospital, Indiana University, Muncie, Indiana, USA.
  • Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino IRCCS, Milan, Italy.
  • Division of Internal Medicine, Ascension Health/Saint Joseph Hospital, Chicago, Illinois, USA.
  • Dow University of Health Sciences, Karachi, Pakistan.
  • Division of Cardiology, UMass Chan School of Medicine, Worcester, Massachusetts, USA.
  • Department of Cardiology, Geisinger Wyoming Valley Medical Center, Wilkes-Barre, Pennsylvania, USA.

ORCID profiles: Mohamad Anas Oudih, Marco Schiavone, Mouaz Oudih, Muhammad Khuzzaim Khan, Majd Al Deen Alhuarrat, Hussam Al Hennawi, Nils Guttenplan

Cite

APA

Oudih, M. A., Schiavone, M., Oudih, M., Khan, M. K., Alhuarrat, M. A. D., Hennawi, H. A., Guttenplan, N., Zou, F., Pugliese, D., Biase, L. D., & other members of the PFA Meta‐Analysis Study Group (2026). Efficacy, Safety, and Procedural Outcomes of Pulsed‐Field Ablation for Paroxysmal Atrial Fibrillation: A Meta‐Analysis. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70375

Vancouver

Oudih MA, Schiavone M, Oudih M, Khan MK, Alhuarrat MAD, Hennawi HA, et al. Efficacy, Safety, and Procedural Outcomes of Pulsed‐Field Ablation for Paroxysmal Atrial Fibrillation: A Meta‐Analysis. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70375

BibTeX
@article{Oudih2026,
  author = {Oudih, Mohamad Anas and Schiavone, Marco and Oudih, Mouaz and Khan, Muhammad Khuzzaim and Alhuarrat, Majd Al Deen and Hennawi, Hussam Al and Guttenplan, Nils and Zou, Fengwei and Pugliese, Daniel and Biase, Luigi Di and other members of the PFA Meta‐Analysis Study Group, other members of the PFA Meta‐Analysis Study Group},
  title = {Efficacy, Safety, and Procedural Outcomes of Pulsed‐Field Ablation for Paroxysmal Atrial Fibrillation: A Meta‐Analysis},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70375}
}
Start for free →