EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the Effect of Electromagnetic Fields Emitted by Electric Vehicles on Cardiac Pacemakers

Tomáš Souček, Adam Urbančík, Lukáš Krčmář

Pacing and Clinical Electrophysiology · 07.07.2026

DOI: 10.1111/pace.70359 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 07.07.2026. Verfasst von Tomáš Souček und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health Studies, Technical University of Liberec, Liberec, Czech Republic. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Student Grant Competition SGS-2024-7482 at the Technical University of Liberec, Faculty of Health Studies in 2024.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pacemakers can be affected by external electromagnetic fields in some cases. For this reason, it is necessary to know the potentially risky sources of interfering fields and the effect they may have on the patient's health. The aim of this paper is to evaluate the risks of using electric vehicles by patients with pacemakers. Measurements of electric and magnetic field strengths were performed in selected models of electric vehicles. Using a custom‐built human body phantom and three explanted Biotronik pacemakers, we assessed whether the emitted fields could affect pacemaker function and whether any observed effects were clinically relevant. Both experiments were conducted under the maximum load in model situations: in the driver and passenger seats, in the back seat and near the charging cable during charging. The electric and magnetic fields detected were not assessed as significant in terms of risk to the pacing system. This study presents preliminary results obtained using pacemakers from a single manufacturer. Based on the monitored electrograms and pacing parameters, no impact on pacemaker function was identified in the three tested Biotronik devices.

Schlagwörter

Stichwörter der Autor:innen

cardiac implantable electronic device (CIED)electric vehicleselectromagnetic interferenceelectromobilitypacemaker

Autor:innen und Institutionen

  • Faculty of Health Studies, Technical University of Liberec, Liberec, Czech Republic.
  • Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic.

Förderung

  • Student Grant Competition SGS-2024-7482 at the Technical University of Liberec, Faculty of Health Studies in 2024

Zitieren

APA

Souček, T., Urbančík, A., & Krčmář, L. (2026). Evaluation of the Effect of Electromagnetic Fields Emitted by Electric Vehicles on Cardiac Pacemakers. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70359

Vancouver

Souček T, Urbančík A, Krčmář L. Evaluation of the Effect of Electromagnetic Fields Emitted by Electric Vehicles on Cardiac Pacemakers. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70359

BibTeX
@article{Souek2026,
  author = {Souček, Tomáš and Urbančík, Adam and Krčmář, Lukáš},
  title = {Evaluation of the Effect of Electromagnetic Fields Emitted by Electric Vehicles on Cardiac Pacemakers},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70359}
}