Journal article in Pacing and Clinical Electrophysiology, published online on 2026-07-02. Written by Moshe Katz and 7 co-authors. Institution: Gray School of Medicine, Tel Aviv University, Tel Aviv, Israel. Cited 1 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

ResumenDatos bibliográficosCiteRelated studies

Abstract (original language)

Introduction

Transvenous pacemakers are effective but carry significant short‐ and long‐term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high‐risk patients ineligible for transvenous systems remain limited.

Aim

To evaluate the real‐world outcomes of leadless pacemaker in high risk bradyarrhythmia patients unsuitable for transvenous pacing.

Methods

A retrospective, observational, multi center registry (MLPI) across four Israeli hospitals, included all patients undergoing leadless pacemaker implantation July 2021‐December 2022 within a national pilot program. Indications included venous abnormalities, prior device infection, Twiddler's syndrome or high infection risk. Procedural success, complications, electrical performance, and mortality were assessed at 48 h, 30 days, and 12 months.

Results

A total of 138 patients were enrolled, with a high comorbidity burden (hypertension 74%, heart failure 44%, chronic kidney disease 36%). High grade atrioventricular block was the main pacing indication (70%), and the leading reason for leadless implantation (54%) was high infection risk. Implantation was successful in 98% of the patients, almost all with Micra. Acute complications occurred in 2.9%, (primarily pericardial effusion); three patients (2.2%) died within 48 h. At 1‐year, electrical performance remained stable, with low pacing thresholds (median 0.5 V), preserved sensing, and declining impedance. Two late complications occurred (tamponade, loss of capture). The 1‐year cumulative complication rate was 4.7%, and all‐cause mortality 12.3%.

Conclusion

Leadless pacemaker implantation in a very high‐risk Israeli cohort achieved high procedural success, stable performance, and low complication rate, supporting its role as a safe and effective alternative to conventional pacing systems.

Authors and institutions

  • Gray School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Davidai Arrhythmia Center, Sheba Medical Center, Tel-Hashomer, Israel.
  • Faculty of Medicine, The Hebrew University, Jerusalem, Israel.
  • Department of Cardiology, Hadassah Medical Center, Jerusalem, Israel.
  • Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel.
  • Department of Cardiology, Rabin Medical Center, Petah Tikva, Israel.

ORCID profiles: Moshe Katz, Yoav Michowitz, Gregory Golovchiner

Cite

APA

Katz, M., Vander, M., Luria, D., Acha, M. R., Michowitz, Y., Barsheshet, A., Golovchiner, G., & Beinart, R. (2026). Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70333

Vancouver

Katz M, Vander M, Luria D, Acha MR, Michowitz Y, Barsheshet A, et al. Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70333

BibTeX
@article{Katz2026,
  author = {Katz, Moshe and Vander, Marianna and Luria, David and Acha, Moshe Rav and Michowitz, Yoav and Barsheshet, Alon and Golovchiner, Gregory and Beinart, Roy},
  title = {Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70333}
}
Start for free →