EUVIMEDAtrasti EUVIMED
Fallbericht

Zero‐Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report

Jianlong Yin, Zhiyong Liao, Daoliang Zhang iD

Pacing and Clinical Electrophysiology · 2026-07-03

DOI: 10.1111/pace.70324 ↗

At a glance

Fallbericht in Pacing and Clinical Electrophysiology, published online on 2026-07-03. Written by Jianlong Yin and 2 co-authors. Institution: Department of Cardiology, Fuwai Shenzhen Hospital, Chinese Academy of Medical Sciences, Shenzhen, China. 7 references. Funded by: "Sanming" Project of Medicine in Shenzhen.

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

A 68‐year‐old man with mirror‐image dextrocardia and symptomatic, drug‐refractory paroxysmal atrial fibrillation underwent zero‐fluoroscopy cryoballoon ablation. Intracardiac echocardiography and 3D electroanatomic mapping were used to guide transseptal puncture, navigate the mirror‐image anatomy, and confirm pulmonary vein occlusion. All four pulmonary veins were successfully isolated without complications. At 1‐year follow‐up, the patient remained asymptomatic without antiarrhythmic medication. This case demonstrates the feasibility and safety of a completely fluoroless cryoballoon ablation strategy in a patient with dextrocardia, effectively overcoming the challenges of complex congenital cardiac anatomy.

Subjects

Author keywords

atrial fibrillationcryoballoon ablationdextrocardiasitus inversuszero‐fluoroscopy

Authors and institutions

  • Department of Cardiology, Fuwai Shenzhen Hospital, Chinese Academy of Medical Sciences, Shenzhen, China.

ORCID profiles: Daoliang Zhang

Funding

  • "Sanming" Project of Medicine in Shenzhen

Cite

APA

Yin, J., Liao, Z., & Zhang, D. (2026). Zero‐Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70324

Vancouver

Yin J, Liao Z, Zhang D. Zero‐Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70324

BibTeX
@article{Yin2026,
  author = {Yin, Jianlong and Liao, Zhiyong and Zhang, Daoliang},
  title = {Zero‐Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70324}
}
Start for free →