Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force
Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1667-1675
DOI: 10.1111/pace.70322 ↗At a glance
Vergleichsstudie in Pacing and Clinical Electrophysiology, published online on 2026-06-10. Written by Sedef Oksuz and 10 co-authors. Institution: Department of Pediatric Cardiology, Izmir City Hospital, Izmir, Turkey. Major MEDLINE topics: Accessory Atrioventricular Bundle, Catheter Ablation, Heart Septum. 12 references.
Abstract (original language)
Introduction
The ablation of septal accessory pathways (APs) in pediatric patients presents significant challenges owing to the close proximity of the atrioventricular (AV) node. Our objective was to assess the influence of contact force (CF)–sensing technology combined with a “conservative force” strategy on procedural efficiency and safety within this high‐risk demographic.
Methods
We retrospectively analyzed 157 pediatric patients who underwent radiofrequency (RF) ablation for septal APs (anteroseptal, midseptal, or posteroseptal). Patients were divided into two groups: the CF group ( n = 77), utilizing a target force of 5–12 g, and the non‐CF group ( n = 80), using conventional irrigated catheters.
Results
The CF group achieved significantly shorter total procedure times (65.0 vs. 80.0 min; p = 0.029) and reduced total RF application times (78.0 vs. 105.0 s; p = 0.047) compared to the non‐CF group. In the CF group, the median CF was 10.0 g, and the median RF power was significantly lower than in the non‐CF group (25 W vs. 30 W; p = 0.003). Subgroup analysis revealed a significant gain in efficiency for posteroseptal (PS) pathways , whereas anteroseptal (AS) pathways required longer procedure times in the CF era due to safety‐driven force titration (105.0 vs. 70.0 min; p = 0.012). Acute success rates (98.7% vs. 93.8%; p = 0.210) and recurrence rates (5.2% vs. 11.3%; p = 0.277) were comparable between the groups. No permanent AV block or major complications occurred in either cohort.
Conclusion
Integrating CF technology with a conservative force strategy (5–12 g) enhances procedural efficiency in pediatric septal AP ablation without compromising safety. While it streamlines the workflow for most septal locations, the AS region requires more meticulous titration, and the midseptal (MS) region remains the most prone to recurrence.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Pediatric Cardiology, Izmir City Hospital, Izmir, Turkey.
- Department of Anesthesiology, Izmir City Hospital, Izmir, Turkey.
- Department of Biostatistics, Izmir Katip Celebi University, Izmir, Turkey.
- Department of Pediatric Cardiology, Izmir Katip Celebi University, Izmir, Turkey.
- Department of Pediatric Cardiology & Pediatric Arrhythmia & Electrophysiology, Izmir Katip Celebi University, Izmir, Turkey.
ORCID profiles: Cem Karadeniz
Cite
APA
Oksuz, S., Atlan, M. A., Yıldız, K., Cirkinoglu, G. G., Dedecengiz, H., Bacak, T., Alimoglu, B., Gerceker, E., Elmalı, F., Narin, N., & Karadeniz, C. (2026). Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force. Pacing and Clinical Electrophysiology, 49(11), 1667-1675. https://doi.org/10.1111/pace.70322
Vancouver
Oksuz S, Atlan MA, Yıldız K, Cirkinoglu GG, Dedecengiz H, Bacak T, et al. Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force. Pacing and Clinical Electrophysiology. 2026;49(11):1667-1675. doi:10.1111/pace.70322
BibTeX
@article{Oksuz2026,
author = {Oksuz, Sedef and Atlan, Muhammed Akif and Yıldız, Kaan and Cirkinoglu, Gozde Gursoy and Dedecengiz, Hakan and Bacak, Tolga and Alimoglu, Berkay and Gerceker, Engin and Elmalı, Ferhan and Narin, Nazmi and Karadeniz, Cem},
title = {Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
volume = {49},
number = {11},
pages = {1667--1675},
doi = {10.1111/pace.70322}
}
EUVIMED