EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force

Sedef Oksuz, Muhammed Akif Atlan, Kaan Yıldız, Gozde Gursoy Cirkinoglu, Hakan Dedecengiz, Tolga Bacak, Berkay Alimoglu, Engin Gerceker, Ferhan Elmalı, Nazmi Narin, Cem Karadeniz iD

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1667-1675

DOI: 10.1111/pace.70322 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 10.06.2026. Verfasst von Sedef Oksuz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Izmir City Hospital, Izmir, Turkey. Hauptthemen laut MEDLINE: Accessory Atrioventricular Bundle, Catheter Ablation, Heart Septum. Die Arbeit nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The ablation of septal accessory pathways (APs) in pediatric patients presents significant challenges owing to the close proximity of the atrioventricular (AV) node. Our objective was to assess the influence of contact force (CF)–sensing technology combined with a “conservative force” strategy on procedural efficiency and safety within this high‐risk demographic.

Methods

We retrospectively analyzed 157 pediatric patients who underwent radiofrequency (RF) ablation for septal APs (anteroseptal, midseptal, or posteroseptal). Patients were divided into two groups: the CF group ( n = 77), utilizing a target force of 5–12 g, and the non‐CF group ( n = 80), using conventional irrigated catheters.

Results

The CF group achieved significantly shorter total procedure times (65.0 vs. 80.0 min; p = 0.029) and reduced total RF application times (78.0 vs. 105.0 s; p = 0.047) compared to the non‐CF group. In the CF group, the median CF was 10.0 g, and the median RF power was significantly lower than in the non‐CF group (25 W vs. 30 W; p = 0.003). Subgroup analysis revealed a significant gain in efficiency for posteroseptal (PS) pathways , whereas anteroseptal (AS) pathways required longer procedure times in the CF era due to safety‐driven force titration (105.0 vs. 70.0 min; p = 0.012). Acute success rates (98.7% vs. 93.8%; p = 0.210) and recurrence rates (5.2% vs. 11.3%; p = 0.277) were comparable between the groups. No permanent AV block or major complications occurred in either cohort.

Conclusion

Integrating CF technology with a conservative force strategy (5–12 g) enhances procedural efficiency in pediatric septal AP ablation without compromising safety. While it streamlines the workflow for most septal locations, the AS region requires more meticulous titration, and the midseptal (MS) region remains the most prone to recurrence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Accessory Atrioventricular BundleCatheter AblationHeart SeptumChildHumansRetrospective StudiesTreatment OutcomeMaleFemaleAdolescent

Stichwörter der Autor:innen

accessory pathwaycontact forcepediatric electrophysiologyradiofrequency ablationseptal pathways

Autor:innen und Institutionen

  • Department of Pediatric Cardiology, Izmir City Hospital, Izmir, Turkey.
  • Department of Anesthesiology, Izmir City Hospital, Izmir, Turkey.
  • Department of Biostatistics, Izmir Katip Celebi University, Izmir, Turkey.
  • Department of Pediatric Cardiology, Izmir Katip Celebi University, Izmir, Turkey.
  • Department of Pediatric Cardiology & Pediatric Arrhythmia & Electrophysiology, Izmir Katip Celebi University, Izmir, Turkey.

ORCID-Profile: Cem Karadeniz

Zitieren

APA

Oksuz, S., Atlan, M. A., Yıldız, K., Cirkinoglu, G. G., Dedecengiz, H., Bacak, T., Alimoglu, B., Gerceker, E., Elmalı, F., Narin, N., & Karadeniz, C. (2026). Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force. Pacing and Clinical Electrophysiology, 49(11), 1667-1675. https://doi.org/10.1111/pace.70322

Vancouver

Oksuz S, Atlan MA, Yıldız K, Cirkinoglu GG, Dedecengiz H, Bacak T, et al. Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force. Pacing and Clinical Electrophysiology. 2026;49(11):1667-1675. doi:10.1111/pace.70322

BibTeX
@article{Oksuz2026,
  author = {Oksuz, Sedef and Atlan, Muhammed Akif and Yıldız, Kaan and Cirkinoglu, Gozde Gursoy and Dedecengiz, Hakan and Bacak, Tolga and Alimoglu, Berkay and Gerceker, Engin and Elmalı, Ferhan and Narin, Nazmi and Karadeniz, Cem},
  title = {Comparison of Procedural Outcomes Across Different Septal Accessory Pathway Locations Using Contact Force},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {11},
  pages = {1667--1675},
  doi = {10.1111/pace.70322}
}
Kostenlos starten →