EUVIMEDEUVIMED entdecken
VergleichsstudieÜbersichtsarbeitOpen Access

Comparison of Invasive Left Atrial Pressure Between Bachmann's Bundle and Right Atrial Appendage Pacing

Eugene S J Tan, Wei Yao Lim, Anand Kailasam, Jie Ying Lee, Li Wei Tan, Kevin Leong, Wee Tiong Yeo, Swee-Chong Seow

Pacing and Clinical Electrophysiology · 2026-08 · 49 (8) · 1058-1066

DOI: 10.1111/pace.70255 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 11.04.2026. Verfasst von Eugene S J Tan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, National University Heart Centre, Singapore, Singapore. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Atrial Pressure, Bundle of His. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Bachmann's bundle pacing (BBP) is associated with shorter p‐wave duration (PWD) and reduced atrial fibrillation (AF) recurrence compared to right atrial appendage pacing (RAAP). We investigated the differences in acute left atrial pressure (LAP) measured invasively between sinus rhythm, BBP and RAAP. Methods and Results Acute LAP and PWD were measured in subjects undergoing left atrial catheter ablation in sinus rhythm, during BBP and RAAP at the end of ablation. Differences in PWD and LAP were determined by paired t‐tests. Among 26 subjects (age 56.6 ± 14.2years, 27% female, 11% left‐sided accessory pathway ablation, 54% pulmonary vein isolation[PVI], 35% PVI+additional LA ablation), BBP was successful in 24 subjects. Adjusted for age, only PWD was significantly associated with LAP in sinus rhythm (ß 0.12, p = 0.039). Compared to sinus rhythm and RAAP, BBP was associated with significantly shorter PWD ( p < 0.05), but LAP was not significantly different ( p > 0.05). In subgroup analyses, BBP remained associated with significantly shorter PWD, but was also associated with lower acute LAP compared to RAAP (16.7 ± 5.5 mmHg vs. 17.0 ± 6.0 mmHg, p = 0.010), among patients with interatrial conduction delay, defined as PWD>120 ms during sinus rhythm. Acute LAP was similar between BBP, sinus rhythm and RAAP in other subgroups (paroxysmal vs. persistent AF, PVI vs. PVI+additional LA ablation, left ventricular ejection fraction 0.05).

Conclusion

Reductions in PWD during BBP did not correspond with uniform reductions with acute LAP. Acute LAP was lower in BBP than RAAP, but its clinical significance in reducing AF requires further study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial AppendageAtrial FibrillationAtrial PressureBundle of HisCardiac Pacing, ArtificialFemaleHumansMaleMiddle AgedCatheter AblationAdultAged

Stichwörter der Autor:innen

Bachmann's bundle pacingatrial fibrillationinter‐atrial conduction delayinvasive hemodynamicsleft atrial pressureright atrial appendage pacing

Autor:innen und Institutionen

  • Department of Cardiology, National University Heart Centre, Singapore, Singapore.
  • Department of Cardiology, Woodlands Health Campus, Singapore, Singapore.

Zitieren

APA

Tan, E. S. J., Lim, W. Y., Kailasam, A., Lee, J. Y., Tan, L. W., Leong, K., Yeo, W. T., & Seow, S. C. (2026). Comparison of Invasive Left Atrial Pressure Between Bachmann's Bundle and Right Atrial Appendage Pacing. Pacing and Clinical Electrophysiology, 49(8), 1058-1066. https://doi.org/10.1111/pace.70255

Vancouver

Tan ESJ, Lim WY, Kailasam A, Lee JY, Tan LW, Leong K, et al. Comparison of Invasive Left Atrial Pressure Between Bachmann's Bundle and Right Atrial Appendage Pacing. Pacing and Clinical Electrophysiology. 2026;49(8):1058-1066. doi:10.1111/pace.70255

BibTeX
@article{Tan2026,
  author = {Tan, Eugene S J and Lim, Wei Yao and Kailasam, Anand and Lee, Jie Ying and Tan, Li Wei and Leong, Kevin and Yeo, Wee Tiong and Seow, Swee-Chong},
  title = {Comparison of Invasive Left Atrial Pressure Between Bachmann's Bundle and Right Atrial Appendage Pacing},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {8},
  pages = {1058--1066},
  doi = {10.1111/pace.70255}
}
Kostenlos starten →