Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation
Pacing and Clinical Electrophysiology · 2026
DOI: 10.1111/pace.70218 ↗At a glance
Journal article in Pacing and Clinical Electrophysiology, 2026. Written by Young Shin Lee and 16 co-authors. Institution: Department of Cardiology, Kyung Hee University Medical Center, Seoul, Republic of Korea. Major MEDLINE topics: Pacemaker, Artificial, Heart Ventricles, Heart Injuries, Prosthesis Implantation. Cited 1 times so far (Crossref); 17 references. The full text is freely available (open access, CC BY-NC 4.0).
Abstract (original language)
Introduction
Leadless pacemakers are typically implanted in the mid‐septum of the right ventricle (RV) to mitigate the risk of perforation. However, reports on the precise location of these implants are limited. This study aimed to elucidate tine‐based leadless pacemaker position and presence of subclinical RV perforation through computed tomography (CT) imaging, along with the associated prognosis.
Methods
Patients who underwent heart, chest or abdomen CT after leadless pacemaker implantation were consecutively included. Two cardiologists and one radiologist reviewed the CT images to assess the position of tines and to detect RV perforation. The implantation position was categorized as the septum, RV free wall, junction of septum and RV free wall, moderator band, and RV apex. Subclinical perforation was defined as the tines of a leadless pacemaker beyond the outer myocardial contour without symptoms, pericardial effusion, hemodynamic instability, or pacemaker malfunction.
Results
A total of 88 patients (age, 72.9 ± 12.1 years; 42 males) were included. The interval between procedure and CT scanning was 8.6 ± 9.2 months. In 68 patients (77.3%), the leadless pacemaker was implanted at the junction of the septum and the RV free wall. Subclinical RV perforation occurred in 15 patients (17.0%). Among patients with RV perforation, the most common implantation site was the junction of the septum and the RV free wall. None of the patients with RV perforation experienced any adverse events for 12.4 ± 12.3 months.
Conclusions
The most common leadless pacemaker implantation site is the junction of the septum and the RV free wall. Subclinical RV perforation is not uncommon and not associated with overt adverse outcomes.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Kyung Hee University Medical Center, Seoul, Republic of Korea.
- Department of Cardiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
- Department of Cardiology, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Gyeonggi-do, Republic of Korea.
- Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
- Department of Cardiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
ORCID profiles: Jae-Sun Uhm, Daehoon Kim, Tae-Hoon Kim, Boyoung Joung
Cite
APA
Lee, Y. S., Uhm, J. S., Park, J. W., Park, S. J., Kim, Y. C., Kim, I. S., Lee, H. J., Kim, M. H., Park, H., Kim, D., Yu, H. T., Kim, T. H., Kim, J. B., Kim, J. Y., Joung, B., Pak, H. N., & Lee, M. H. (2026). Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70218
Vancouver
Lee YS, Uhm JS, Park JW, Park SJ, Kim YC, Kim IS, et al. Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70218
BibTeX
@article{Lee2026,
author = {Lee, Young Shin and Uhm, Jae-Sun and Park, Je-Wook and Park, Seung-Jung and Kim, Ye Chan and Kim, In-Soo and Lee, Hye-Jeong and Kim, Moon-Hyun and Park, Hanjin and Kim, Daehoon and Yu, Hee Tae and Kim, Tae-Hoon and Kim, Jin-Bae and Kim, Jong-Youn and Joung, Boyoung and Pak, Hui-Nam and Lee, Moon-Hyoung},
title = {Impact of Leadless Pacemaker Implantation Position on Subclinical Right Ventricular Perforation},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70218}
}
EUVIMED