EUVIMEDSkopri EUVIMED
Vergleichsstudie

Comparative Left Bundle Branch Block Correction With Physiological Pacing—An Intrapatient Electrocardiographic Study

Catalin Pestrea iD, Ecaterina Cicala, Sever Risca, Dana Clapon, Florin Ortan

Pacing and Clinical Electrophysiology · 2026-07 · 49 (7) · 917-924

DOI: 10.1111/pace.70179 ↗

At a glance

Vergleichsstudie in Pacing and Clinical Electrophysiology, published online on 2026-02-24. Written by Catalin Pestrea and 4 co-authors. Institution: Department of Interventional Cardiology, Brasov County Clinical Emergency Hospital, Brasov, Romania. Major MEDLINE topics: Bundle-Branch Block, Electrocardiography, Cardiac Pacing, Artificial, Cardiac Resynchronization Therapy. Cited 1 times so far (Crossref); 28 references.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Introduction

Several studies have compared His bundle pacing (HBP) and left bundle branch area pacing (LBBAP) regarding paced QRS duration and clinical outcomes. This study compared acute intraprocedural depolarization and repolarization electrocardiographic changes between corrective HBP and LBBAP in the same patient with baseline left bundle branch block and reduced left ventricular ejection fraction. Material and Methods Thirty‐six patients with successful corrective LBBAP for cardiac resynchronization therapy (CRT), in whom corrective HBP was also demonstrated, were retrospectively reviewed. QRS duration (QRSd), QRS and T wave axes, left ventricular activation time (LVAT), corrected QT (QTc) and JT (JTc) intervals, QT dispersion (QTd), corrected T wave peak‐to‐end interval (Tpec) and Tpec/QTc were measured for both instances.

Results

Both pacing techniques produced significantly narrower QRS complexes than the baseline values without differences between them. The LVAT was shorter with HBP than baseline without reaching statistical significance. On the other hand, LBBAP was associated with significantly shorter LVATs than both baseline and HBP values. HBP and LBBAP had a similar impact on repolarization parameters, significantly reducing the QTc, JTc and Tpec. Final left bundle branch pacing was achieved in 24 and final left ventricular septal pacing in 12 patients. The former resulted in a shorter QRS duration and a significantly faster LVAT. Also, capturing the left conduction system reduced the QTc and JTc intervals, albeit without statistical significance.

Conclusion

In patients with LBBB and an indication for resynchronization therapy, HBP and LBBAP resulted in similar significant improvements in electrocardiographic depolarization and repolarization parameters.

Subjects

MeSH terms (MEDLINE)

Bundle-Branch BlockElectrocardiographyCardiac Pacing, ArtificialCardiac Resynchronization TherapyHumansFemaleMaleBundle of HisRetrospective StudiesAgedTreatment Outcome

Author keywords

His bundle pacingdepolarization parametersleft bundle branch area pacingleft bundle branch blockrepolarization parameters

Authors and institutions

  • Department of Interventional Cardiology, Brasov County Clinical Emergency Hospital, Brasov, Romania.

ORCID profiles: Catalin Pestrea

Cite

APA

Pestrea, C., Cicala, E., Risca, S., Clapon, D., & Ortan, F. (2026). Comparative Left Bundle Branch Block Correction With Physiological Pacing—An Intrapatient Electrocardiographic Study. Pacing and Clinical Electrophysiology, 49(7), 917-924. https://doi.org/10.1111/pace.70179

Vancouver

Pestrea C, Cicala E, Risca S, Clapon D, Ortan F. Comparative Left Bundle Branch Block Correction With Physiological Pacing—An Intrapatient Electrocardiographic Study. Pacing and Clinical Electrophysiology. 2026;49(7):917-924. doi:10.1111/pace.70179

BibTeX
@article{Pestrea2026,
  author = {Pestrea, Catalin and Cicala, Ecaterina and Risca, Sever and Clapon, Dana and Ortan, Florin},
  title = {Comparative Left Bundle Branch Block Correction With Physiological Pacing—An Intrapatient Electrocardiographic Study},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {7},
  pages = {917--924},
  doi = {10.1111/pace.70179}
}
Start for free →