EUVIMEDОткрийте EUVIMED
FallberichtOpen access · CC BY-NC-ND 4.0

Transthoracic Echocardiography‐Guided Implantation of Aveir VR Leadless Pacemaker Without Fluoroscopy

Haojie Zhu, Pingping Gao, Fujian Duan, Xiaohan Fan, Xiangbin Pan iD

Pacing and Clinical Electrophysiology · 2026-08 · 49 (8) · 1121-1123

DOI: 10.1111/pace.70176 ↗

At a glance

Fallbericht in Pacing and Clinical Electrophysiology, published online on 2026-02-27. Written by Haojie Zhu and 4 co-authors. Institution: Cardiac Arrhythmia Center, Fuwai Hospital, National Center For Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical …. Major MEDLINE topics: Pacemaker, Artificial, Echocardiography, Prosthesis Implantation, Ultrasonography, Interventional. The full text is freely available (open access, CC BY-NC-ND 4.0).

РезюмеSubjectsБиблиографски данниCiteRelated studies

Abstract (original language)

Background

Leadless pacemaker implantation traditionally relies on fluoroscopy and contrast‐guided techniques. However, in patients with advanced chronic kidney disease, the use of contrast carries a risk of nephrotoxicity, and fluoroscopy leads to additional ionizing radiation exposure. Case Summary We report a case of a 69‐year‐old man with occasional sinus arrest and end‐stage renal disease on hemodialysis who successfully underwent implantation of an Aveir VR leadless pacemaker (Abbott, USA) entirely under transthoracic echocardiographic (TTE) guidance, without fluoroscopy or contrast. Using a Philips EPIQ system with an X5‐1 transducer, key procedural steps—including navigation, septal positioning, pacing threshold testing, and final deployment—were completed under real‐time ultrasound visualization. Post‐procedural pacing parameters were optimal, and no complications occurred. Chest radiography confirmed appropriate device position.

Conclusion

This case demonstrates the potential feasibility and safety of an ultrasound‐guided implantation technique for the Aveir VR leadless pacemaker. It may offer a promising alternative for patients with contraindications to radiation or contrast agents. Larger studies are needed to validate and standardize this approach.

Subjects

MeSH terms (MEDLINE)

Pacemaker, ArtificialEchocardiographyProsthesis ImplantationUltrasonography, InterventionalSurgery, Computer-AssistedHumansMaleAgedKidney Failure, ChronicFluoroscopyTreatment Outcome

Authors and institutions

  • Cardiac Arrhythmia Center, Fuwai Hospital, National Center For Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Echocardiography, Fuwai Hospital, National Center For Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Structural Heart Disease, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

ORCID profiles: Xiangbin Pan

Cite

APA

Zhu, H., Gao, P., Duan, F., Fan, X., & Pan, X. (2026). Transthoracic Echocardiography‐Guided Implantation of Aveir VR Leadless Pacemaker Without Fluoroscopy. Pacing and Clinical Electrophysiology, 49(8), 1121-1123. https://doi.org/10.1111/pace.70176

Vancouver

Zhu H, Gao P, Duan F, Fan X, Pan X. Transthoracic Echocardiography‐Guided Implantation of Aveir VR Leadless Pacemaker Without Fluoroscopy. Pacing and Clinical Electrophysiology. 2026;49(8):1121-1123. doi:10.1111/pace.70176

BibTeX
@article{Zhu2026,
  author = {Zhu, Haojie and Gao, Pingping and Duan, Fujian and Fan, Xiaohan and Pan, Xiangbin},
  title = {Transthoracic Echocardiography‐Guided Implantation of Aveir VR Leadless Pacemaker Without Fluoroscopy},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {8},
  pages = {1121--1123},
  doi = {10.1111/pace.70176}
}
Start for free →