Pulsed Field Ablation for Atrial Fibrillation in Patients With Obesity: Procedural and Clinical Outcomes
Pacing and Clinical Electrophysiology · 2026
DOI: 10.1111/pace.70145 ↗At a glance
Beobachtungsstudie in Pacing and Clinical Electrophysiology, 2026. Written by Francis J Ha and 6 co-authors. Institution: Victorian Heart Institute and Victorian Heart Hospital, Monash University, Clayton, Victoria, Australia. Major MEDLINE topics: Atrial Fibrillation, Obesity, Catheter Ablation. Cited 2 times so far (Crossref); 32 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Background
Procedural and clinical outcomes in patients with obesity undergoing catheter ablation for atrial fibrillation (AF) have been mixed. Clinical data in the context of pulsed field ablation (PFA) are currently limited in this patient cohort.
Methods
We conducted an observational study of consecutive patients undergoing PFA with a pentaspline catheter (Farapulse TM , Boston Scientific) for AF at a tertiary center comparing procedural and clinical outcomes in patients with body mass index (BMI) 30 s at any follow‐up.
Results
537 (95%) out of 564 consecutive patients underwent de novo PFA for AF between 2022 and 2025 with a recorded BMI; 326 (60.7%) were nonobese, 117 (21.8%) were obese and 94 (17.5%) morbidly obese patients. Proportion of females increased according to BMI ( p = 0.003). Obesity correlated with CHA 2 DS 2 ‐VASc score, hypertension, diabetes mellitus, obstructive sleep apnea and heart failure with reduced ejection fraction ( p < 0.05 for all). Persistent AF was more common ( p = 0.048). Radiation exposure was significantly increased in obese patients ( p < 0.001). There was no difference in major (1.2%–3.2%) or minor (11%–15%) procedural complications between groups. There was no difference in freedom from arrhythmia recurrence between groups (67%–70% at median follow‐up 5.9–7.4 months).
Conclusion
Patients with obesity had no signal of increased risk detected with regard to procedural safety and clinical outcomes with PFA for AF compared with nonobese patients. These findings apply to a specific pentaspline PFA catheter rather than PFA technology in general.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Victorian Heart Institute and Victorian Heart Hospital, Monash University, Clayton, Victoria, Australia.
ORCID profiles: Francis J Ha, Duron Prinsloo
Cite
APA
Ha, F. J., Prinsloo, D., Xu, E., Han, H. C., Nerlekar, N., Brown, A. J., & Kotschet, E. (2026). Pulsed Field Ablation for Atrial Fibrillation in Patients With Obesity: Procedural and Clinical Outcomes. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70145
Vancouver
Ha FJ, Prinsloo D, Xu E, Han HC, Nerlekar N, Brown AJ, et al. Pulsed Field Ablation for Atrial Fibrillation in Patients With Obesity: Procedural and Clinical Outcomes. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70145
BibTeX
@article{Ha2026,
author = {Ha, Francis J and Prinsloo, Duron and Xu, Edwin and Han, Hui Chen and Nerlekar, Nitesh and Brown, Adam J and Kotschet, Emily},
title = {Pulsed Field Ablation for Atrial Fibrillation in Patients With Obesity: Procedural and Clinical Outcomes},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70145}
}
EUVIMED