EUVIMEDObjevte EUVIMED
Vergleichsstudie

Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation

Kohki Kimura iD, Jun Morita, Makoto Idoji, Toka Hamaguchi, Mariko Yano, Tetsuya Haruna

Pacing and Clinical Electrophysiology · 2026

DOI: 10.1111/pace.70129 ↗

At a glance

Vergleichsstudie in Pacing and Clinical Electrophysiology, 2026. Written by Kohki Kimura and 5 co-authors. Institution: Cardiovascular Center, Medical Research Institute Kitano Hospital, Osaka City, Osaka, Japan. Major MEDLINE topics: Atrial Fibrillation, Heart Atria, Echocardiography, Catheter Ablation. Cited 1 times so far (Crossref); 15 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Pulsed field ablation (PFA) is an emerging, effective therapy for atrial fibrillation (AF). Achieving adequate catheter‐to‐tissue contact is crucial, as poor contact can result in pulmonary vein (PV) reconnection or hemolysis. Intracardiac echocardiography (ICE) enables real‐time visualization of the PFA catheter and PV anatomy. To compare the utility of left atrial (LA) versus right atrial (RA) ICE placement during PFA for AF.

Methods

We retrospectively analyzed 53 consecutive AF patients who underwent index PFA procedures (FARAWAVE, Boston Scientific). Patients were stratified into two groups according to ICE location: RA‐ICE ( n = 20) and LA‐ICE ( n = 33). Procedural characteristics and image quality of catheter and PV anatomy were evaluated.

Results

The total number of PFA applications was higher in the LA‐ICE group than in the RA‐ICE group (45.6 ± 6.8 vs. 35.8 ± 3.4, p < 0.01). Nevertheless, LA‐ICE was associated with a shorter LA dwell time (45.4 ± 13.3 vs. 55.0 ± 17.1 min, p = 0.04) and PV isolation time (19.6 ± 3.9 vs. 25.4 ± 10.5 min, p = 0.01). Visualization of catheter configuration and PV anatomy was significantly better in the LA‐ICE group, particularly for the left inferior and right‐sided PVs ( p < 0.01).

Conclusions

ICE placement in the LA improved visualization of the PFA catheter and PV anatomy, resulting in reduced PV isolation and LA dwell times compared with RA‐ICE.

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationHeart AtriaEchocardiographyCatheter AblationUltrasonography, InterventionalHumansFemaleRetrospective StudiesMaleTreatment OutcomeIrreversible Electroporation TherapyMiddle AgedAgedPulmonary Veins

Author keywords

atrial fibrillationcatheter ablationintracardiac echocardiographyleft atriumpulmonary veinpulsed field ablation

Authors and institutions

  • Cardiovascular Center, Medical Research Institute Kitano Hospital, Osaka City, Osaka, Japan.

ORCID profiles: Kohki Kimura

Cite

APA

Kimura, K., Morita, J., Idoji, M., Hamaguchi, T., Yano, M., & Haruna, T. (2026). Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70129

Vancouver

Kimura K, Morita J, Idoji M, Hamaguchi T, Yano M, Haruna T. Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70129

BibTeX
@article{Kimura2026,
  author = {Kimura, Kohki and Morita, Jun and Idoji, Makoto and Hamaguchi, Toka and Yano, Mariko and Haruna, Tetsuya},
  title = {Comparing Left Versus Right Atrial Intracardiac Echocardiography in Pulsed Field Ablation for Atrial Fibrillation},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70129}
}
Start for free →