Repolarization Abnormalities in Patients with Takotsubo Syndrome Versus Acute Anterior Myocardial Infarction
Pacing and Clinical Electrophysiology · 2025
DOI: 10.1111/pace.70098 ↗At a glance
Vergleichsstudie in Pacing and Clinical Electrophysiology, 2025. Written by Pinchao Lv and 4 co-authors. Institution: Department of Geriatrics, Peking University First Hospital, Beijing, China. Major MEDLINE topics: Takotsubo Cardiomyopathy, Electrocardiography, Anterior Wall Myocardial Infarction. 24 references. Funded by: Key Program of the National Natural Science Foundation of China, General Program of the National Natural Science Foundation of China.
Abstract (original language)
Objectives
Takotsubo syndrome (TTS) is characterized by ST‐segment deviations and T‐wave inversions in electrocardiogram (ECG) recordings, accompanied by an increased risk of ventricular arrhythmias. This study aimed to investigate the repolarization abnormalities of ECG parameters in TTS patients by comparing them with those of acute anterior myocardial infarction (AMI).
Methods
A total of 168 patients diagnosed with TTS, AMI of the anterior wall, and matched controls who underwent coronary angiogram were enrolled from 962 consecutive admissions. ECG repolarization parameters were measured and analyzed.
Results
After matching, there were no significant differences in baseline characteristics among the TTS ( n = 24), AMI ( n = 72), and matched control ( n = 72) groups ( p > 0.05). Compared with matched controls, both the TTS and AMI groups had significantly increased QTc ( p < 0.001), QT dispersion ( p < 0.001), and T p‐e dispersion ( p < 0.001). However, in the subacute phase, TTS patients exhibited significantly more severe repolarization abnormalities compared with those with anterior wall AMI, including increased T p‐e ( p < 0.001), T p‐e dispersion ( p = 0.002), and T p‐e /QTc ratio ( p < 0.001). ECG indicators showed that the areas under the receiver operating characteristic (ROC) curves for differentiating TTS from AMI using T p‐e /QTc ratio, T p‐e , and T p‐e dispersion were 0.78, 0.74, and 0.71, respectively. Furthermore, T p‐e dispersion and QT dispersion were also associated with ventricular arrhythmias in patients with TTS and AMI, respectively, indicating that these ECG parameters are valuable for identifying TTS and predicting arrhythmias.
Conclusions
TTS is associated with increased QT dispersion, T p‐e , T p‐e dispersion, and T p‐e /QTc ratio when compared with anterior wall AMI and matched controls. These distinct repolarization abnormalities may be related to the occurrence of ventricular arrhythmias.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Geriatrics, Peking University First Hospital, Beijing, China.
- Department of Cardiology, Peking University First Hospital, Beijing, China.
- Department of Critical Care Medicine, Peking University First Hospital, Beijing, China.
- State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing, China.
- Department of Cardiology, First Affiliated Hospital of Jinzhou Medical University, Jinzhou, China.
ORCID profiles: Pinchao Lv
Funding
- Key Program of the National Natural Science Foundation of China
- General Program of the National Natural Science Foundation of China
Cite
APA
Lv, P., Fan, F., Li, S., Li, K., & Wu, L. (2025). Repolarization Abnormalities in Patients with Takotsubo Syndrome Versus Acute Anterior Myocardial Infarction. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70098
Vancouver
Lv P, Fan F, Li S, Li K, Wu L. Repolarization Abnormalities in Patients with Takotsubo Syndrome Versus Acute Anterior Myocardial Infarction. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70098
BibTeX
@article{Lv2025,
author = {Lv, Pinchao and Fan, Fangfang and Li, Shuangling and Li, Kang and Wu, Lin},
title = {Repolarization Abnormalities in Patients with Takotsubo Syndrome Versus Acute Anterior Myocardial Infarction},
journal = {Pacing and Clinical Electrophysiology},
year = {2025},
doi = {10.1111/pace.70098}
}
EUVIMED