EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Comparison of Valvular and Ventricular Function After Right Ventricular, Leadless, Deep Septal, and Left Bundle Branch Area Pacemakers

Anja Zhou iD, Isabelle Andersson, Mutaz Alkalbani, Abbas Emaminia, Eunice Yang, Martin Ugander, Brett D Atwater

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.70087 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Anja Zhou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology, Karolinska University Hospital, and Karolinska Institute, Stockholm, Sweden. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Cardiac Pacing, Artificial, Atrioventricular Block, Tricuspid Valve Insufficiency. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Inova Health System, Karolinska Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Changes in tricuspid regurgitation (TR), mitral regurgitation (MR), and left ventricular ejection fraction (LVEF) are frequently noted after right ventricular apical (RVA) pacemaker implantation but prior studies evaluating whether left bundle branch area (LBBA), deep septal (DS), or leadless pacemaker implantation modify risk for those changes are limited. This study aims to compare changes in TR, MR, and LVEF after implantation of RVA, LBBA, DS, and leadless pacemakers.

Methods

Patients were included if they underwent de novo pacemaker implantation for sinus node dysfunction or atrioventricular block and received pre‐ and post‐implant echocardiography. Change in TR, MR, and LVEF were analyzed using post‐hoc adjusted Kruskal–Wallis and Chi‐squared testing, and multivariable ordinal logistic regression.

Results

Among 386 consecutive patients (RV, n = 185; LBBA, n = 122; DS, n = 43, leadless, n = 36) the change in TR grade differed between pacemaker types (median [interquartile range] grade change: RVA 0[0,1], leadless 0[0,1], DS 0[0,1], LBBA 0[0,0]; p = 0.01). In multivariable ordinal logistic regression, leadless (OR 2.41, p = 0.01) and DS pacemakers (OR 2.44, p < 0.01) predicted TR worsening compared to LBBA. The change in MR grade also differed between pacemaker types (grade change: RVA 0[0,1], leadless 0[0,1], DS 0[0,0], LBBA 0[−1,0]; p = 0.03). The change in LVEF differed between pacemaker types (LVEF change: RVA −3[−9,3]%, leadless −5[−14,1]%, DS −3[−11,0]%, LBBA −1[−5,5]%; p < 0.01).

Conclusion

The change in TR and MR grade and LVEF following pacemaker implant varied by pacemaker type. Compared to implantation with RVA, leadless, and DS pacemakers, LBBA pacemaker implantation was associated with more favorable changes in valvular and ventricular function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialCardiac Pacing, ArtificialAtrioventricular BlockTricuspid Valve InsufficiencyMitral Valve InsufficiencySick Sinus SyndromeHeart VentriclesStroke VolumeEchocardiographyLogistic ModelsMultivariate AnalysisRetrospective StudiesSeverity of Illness IndexHumansMaleFemaleAgedAged, 80 and overEquipment Design

Stichwörter der Autor:innen

cardiac pacemakersechocardiographyleft ventricular ejection fractionmitral regurgitationtricuspid regurgitation

Autor:innen und Institutionen

  • Department of Clinical Physiology, Karolinska University Hospital, and Karolinska Institute, Stockholm, Sweden.
  • Inova Schar Heart and Vascular, Falls Church, Virginia, USA.
  • Kolling Institute, Royal North Shore Hospital, and University of Sydney, St Leonard's, Sydney, Australia.

ORCID-Profile: Anja Zhou

Förderung

  • Inova Health System
  • Karolinska Institute

Zitieren

APA

Zhou, A., Andersson, I., Alkalbani, M., Emaminia, A., Yang, E., Ugander, M., & Atwater, B. D. (2025). Comparison of Valvular and Ventricular Function After Right Ventricular, Leadless, Deep Septal, and Left Bundle Branch Area Pacemakers. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70087

Vancouver

Zhou A, Andersson I, Alkalbani M, Emaminia A, Yang E, Ugander M, et al. Comparison of Valvular and Ventricular Function After Right Ventricular, Leadless, Deep Septal, and Left Bundle Branch Area Pacemakers. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70087

BibTeX
@article{Zhou2025,
  author = {Zhou, Anja and Andersson, Isabelle and Alkalbani, Mutaz and Emaminia, Abbas and Yang, Eunice and Ugander, Martin and Atwater, Brett D},
  title = {Comparison of Valvular and Ventricular Function After Right Ventricular, Leadless, Deep Septal, and Left Bundle Branch Area Pacemakers},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.70087}
}
Kostenlos starten →