Comparison of 6‐mm and 8‐mm Tip Cryoablation Catheters in the Treatment of Pediatric AVNRT
Pacing and Clinical Electrophysiology · 2025
DOI: 10.1111/pace.70079 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Nevin Özdemiroğlu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Ankara Bilkent City Hospital, Ankara, Turkiye. Hauptthemen laut MEDLINE: Cryosurgery, Tachycardia, Atrioventricular Nodal Reentry. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
Radiofrequency (RF) ablation has long been the standard treatment for atrioventricular nodal reentrant tachycardia (AVNRT) in children. However, cryoablation (CA) has gained popularity due to its safety profile and acceptable long‐term success rates. Comparative data on different CA catheter tip sizes in pediatric AVNRT are limited.
Objective
To compare the acute and long‐term outcomes of 6‐mm vs. 8‐mm tip CA catheters in pediatric patients undergoing AVNRT ablation. Methods and Results This retrospective single‐center study included 129 pediatric patients (76 female, mean age 13 ± 3.0 years, mean weight 51.7 ± 15.7 kg) who underwent CA for AVNRT between January 2016 and December 2022. A 6‐mm tip catheter was used in 64 patients and an 8‐mm tip catheter in 65 patients. All procedures were performed using a three‐dimensional electroanatomical mapping system (EAMS) (EnSite, Abbott/St. Jude Medical Inc., St. Paul, MN, USA), with minimal or no fluoroscopy in most cases. Acute success, recurrence rates, procedural parameters, and complications were compared between groups. Of the 129 patients, 126 (97.7%) had typical AVNRT and 3 (2.3%) had atypical AVNRT. The mean procedure time was 151.9 ± 43 min, with no significant difference between groups. Acute success rates were 100% in the 6‐mm group and 98.5% in the 8‐mm group ( p > 0.05). The mean number of cryolesions was 8.5 ± 2.3 (6‐mm) and 9.0 ± 2.5 (8‐mm) ( p > 0.05). Over a mean follow‐up of 31.4 ± 26 months, recurrences occurred in six patients (4.6%), all successfully re‐ablated. Long‐term success rates were 94.4% overall, with no significant difference between groups. No permanent complications occurred; transient AV block was observed in one patient (0.7%).
Conclusions
Both 6‐mm and 8‐mm CA catheters achieve high acute success and low recurrence rates in pediatric AVNRT with similar safety profiles. Catheter tip size can be tailored to patient age and weight without compromising efficacy. Minimal fluoroscopy approaches can be applied safely in the majority of cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, Ankara Bilkent City Hospital, Ankara, Turkiye.
- Department of Pediatric Cardiac Electrophysiology, Ankara Bilkent City Hospital, Ankara, Turkiye.
ORCID-Profile: Nevin Özdemiroğlu, Emine Gülşah Torun, Gökçe Kaş, Harun Terin, Serhat Koca
Zitieren
APA
Özdemiroğlu, N., Torun, E. G., Kaş, G., Ekşi, M. A., Terin, H., & Koca, S. (2025). Comparison of 6‐mm and 8‐mm Tip Cryoablation Catheters in the Treatment of Pediatric AVNRT. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70079
Vancouver
Özdemiroğlu N, Torun EG, Kaş G, Ekşi MA, Terin H, Koca S. Comparison of 6‐mm and 8‐mm Tip Cryoablation Catheters in the Treatment of Pediatric AVNRT. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70079
BibTeX
@article{zdemirolu2025,
author = {Özdemiroğlu, Nevin and Torun, Emine Gülşah and Kaş, Gökçe and Ekşi, Muhammed Ali and Terin, Harun and Koca, Serhat},
title = {Comparison of 6‐mm and 8‐mm Tip Cryoablation Catheters in the Treatment of Pediatric AVNRT},
journal = {Pacing and Clinical Electrophysiology},
year = {2025},
doi = {10.1111/pace.70079}
}
EUVIMED