Vergleichsstudie in der Zeitschrift Cardiology in the Young, 2025. Verfasst von Pinar Kanlioglu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Heal…. Hauptthemen laut MEDLINE: Catheter Ablation, Imaging, Three-Dimensional, Tachycardia, Ventricular, Heart Ventricles. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
Objective
We compared the results of conventional electroanatomic mapping and high-density mapping in ablations of the right ventricular outflow tract. Materials and methods: Between 2014 and 2024, a total of 92 patients underwent ablation using an electroanatomic mapping system. A contact force radiofrequency ablation catheter was used in all patients, except for two who underwent cryoablation.
Results
Our study comprised two groups, with a total of 92 patients. Among them, 45 patients underwent conventional three-dimensional mapping, while 47 patients underwent high-density three-dimensional mapping. In both groups, there were three patients with nonsustained ventricular tachycardia and two patients with sustained ventricular tachycardia, and there was no statistically significant difference in the frequency of ventricular premature contractions between the two groups. There were four patients with systolic dysfunction in the high-density mapping group and four in the conventional mapping group. In the high-density mapping group, the procedure time was significantly shorter. There was a notable difference regarding the reduced fluoroscopy time. The total lesion time and number were also significantly lower in the high-density mapping group. The earliest activation time was significantly longer in this group. The procedure’s success rate was 97.9% for the high-density mapping group and 93.4% for the conventional mapping group. Successful ablation was performed on one ventricular extrasystole in the parahisian localisation in each group, while a cooled type radiofrequency catheter was used for all other cases.
Conclusion
In children with right ventricular outflow tract arrhythmias, high-density mapping can be used with high success rates and safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, İstanbul, Turkey.
ORCID-Profile: Şevket Ballı
Zitieren
APA
Kanlioglu, P., Ballı, Ş., Arıkan, O. Ç., & Sultan, B. (2025). Comparison of ablation results using three-dimensional conventional mapping and high-density mapping in right ventricular outflow tract arrhythmias in paediatric patients. Cardiology in the Young. https://doi.org/10.1017/s1047951125100796
Vancouver
Kanlioglu P, Ballı Ş, Arıkan OÇ, Sultan B. Comparison of ablation results using three-dimensional conventional mapping and high-density mapping in right ventricular outflow tract arrhythmias in paediatric patients. Cardiology in the Young. 2025. doi:10.1017/s1047951125100796
BibTeX
@article{Kanlioglu2025,
author = {Kanlioglu, Pinar and Ballı, Şevket and Arıkan, Onur Çağdaş and Sultan, Bent},
title = {Comparison of ablation results using three-dimensional conventional mapping and high-density mapping in right ventricular outflow tract arrhythmias in paediatric patients},
journal = {Cardiology in the Young},
year = {2025},
doi = {10.1017/s1047951125100796}
}
EUVIMED