EUVIMEDSkopri EUVIMED
VergleichsstudieOpen access · CC BY-NC-ND 4.0

Safety of Same‐Day Discharge Following Pulsed‐Field Ablation Versus Radiofrequency Ablation: A Comparative Analysis

Adele Watfa iD, Arwa Younis, Mohamad Mdaihly, Joe Demian, Chadi Tabaja, Pasquale Santangeli, Bryan Baranowski, Hiroshi Nakagawa, Tyler Louis Taigen, Koji Higuchi, Thomas D Callahan, Shady Nakhla iD and 8 more

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.70005 ↗

At a glance

Vergleichsstudie in Pacing and Clinical Electrophysiology, 2025. Written by Adele Watfa and 19 co-authors. Institution: Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA. Major MEDLINE topics: Atrial Fibrillation, Catheter Ablation, Patient Discharge, Radiofrequency Ablation. Cited 7 times so far (Crossref); 13 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Same‐day discharge (SDD) after catheter ablation is increasingly adopted to improve patient convenience and reduce healthcare costs. While SDD following radiofrequency ablation (RFA) is well‐documented, no data exist on SDD in patients undergoing pulsed‐field ablation (PFA) for atrial fibrillation (AF).

Objective

To evaluate the safety of SDD in patients undergoing PFA and RFA for AF, with an exploratory comparison of practice patterns and outcomes.

Methods

From a prospectively maintained registry, we included all consecutive patients undergoing PFA for AF (FARAWAVE catheter) since its FDA approval and patients undergoing AF RFA between March and October 2023 (comparison group). Outcomes included rates of major complications (vascular complications, cerebrovascular accidents, transient ischemic attacks (TIA), phrenic nerve injury, and pericardial effusion requiring intervention), minor complications, readmissions within 30 days, and all‐cause mortality.

Results

The study included 955 PFA patients, of whom 207 (21.7%) were discharged the same day, and 1072 RFA patients, of whom 127 (11.8%) were discharged the same day. Vascular closure modalities differed significantly across groups ( p < 0.001). Major complications, including stroke and TIA, occurred in 0.5% of PFA non‐SDD and 1.1% of RFA non‐SDD patients ( p = 0.29, p = 0.24), with no major complications in SDD groups and no deaths across all groups. Minor complications were 0.5% for PFA SDD versus 1.1% for PFA non‐SDD ( p = 0.44) and 1.6% for both RFA SDD and RFA non‐SDD ( p = 0.99), and not significantly different between PFA SDD and RFA SDD ( p = 0.31). Readmission rates (UTI, AF, aspiration pneumonia) were similar between SDD patients at 1.4% for PFA and 2.4% for RFA ( p = 0.54). A lower CHA2DS2‐VASc score predicted the practice pattern of SDD in the PFA cohort (OR = 0.754, 95% CI: 0.663–0.858, p < 0.001), while being octogenarian reduced the likelihood of SDD (OR = 0.265, 95% CI: 0.105–0.666, p = 0.005).

Conclusion

In this cohort, SDD was found to be a safe and viable option for both PFA and RFA. In this practice, the rates of same‐day discharge were higher in the PFA group versus the RFA group and is being increasingly adopted.

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationCatheter AblationPatient DischargeRadiofrequency AblationAgedFemaleHumansMaleMiddle AgedPatient SafetyPostoperative ComplicationsProspective StudiesRegistries

Author keywords

atrial fibrillationcomplicationsprocedural safetypulsed‐field ablationradiofrequency ablationsame‐day discharge

Authors and institutions

  • Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

ORCID profiles: Adele Watfa, Shady Nakhla

Cite

APA

Watfa, A., Younis, A., Mdaihly, M., Demian, J., Tabaja, C., Santangeli, P., Baranowski, B., Nakagawa, H., Taigen, T. L., Higuchi, K., Callahan, T. D., Nakhla, S., Kanj, M., Chung, M. K., Sroubek, J., Lee, J. Z., Bhargava, M., Saliba, W. I., Wazni, O. M., & Hussein, A. A. (2025). Safety of Same‐Day Discharge Following Pulsed‐Field Ablation Versus Radiofrequency Ablation: A Comparative Analysis. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70005

Vancouver

Watfa A, Younis A, Mdaihly M, Demian J, Tabaja C, Santangeli P, et al. Safety of Same‐Day Discharge Following Pulsed‐Field Ablation Versus Radiofrequency Ablation: A Comparative Analysis. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70005

BibTeX
@article{Watfa2025,
  author = {Watfa, Adele and Younis, Arwa and Mdaihly, Mohamad and Demian, Joe and Tabaja, Chadi and Santangeli, Pasquale and Baranowski, Bryan and Nakagawa, Hiroshi and Taigen, Tyler Louis and Higuchi, Koji and Callahan, Thomas D and Nakhla, Shady and Kanj, Mohamed and Chung, Mina K and Sroubek, Jakub and Lee, Justin Z and Bhargava, Mandeep and Saliba, Walid I and Wazni, Oussama M and Hussein, Ayman A},
  title = {Safety of Same‐Day Discharge Following Pulsed‐Field Ablation Versus Radiofrequency Ablation: A Comparative Analysis},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.70005}
}
Start for free →