EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Depression and Anxiety in Patients Who Received a CRT Device and Did Not Have Shock Therapy During a 12‐Month Follow‐Up

Elizabeth Florou, Dimitrios Sfairopoulos, Sofia Plakoutsi, Aris Bechlioulis, Konstantinos Zekios, Haralampos Milionis, Petros Skapinakis, Panagiotis Korantzopoulos

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.70002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Elizabeth Florou und 7 weiteren Autor:innen. Beteiligte Einrichtung: First Department of Cardiology, University of Ioannina Medical School, Ioannina, Greece. Hauptthemen laut MEDLINE: Anxiety, Heart Failure, Depression, Cardiac Resynchronization Therapy Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Cardiac resynchronization therapy (CRT) may affect the patients’ psychological status differently in various populations. There are limited data regarding depression and anxiety in this setting, while there are no data regarding Greek patients.

Methods

We studied heart failure with reduced ejection fraction (HFrEF) patients, without conditions affecting psychological status, undergoing CRT. We used the Minnesota Living with Heart Failure Questionnaire (MLHFQ), the 9‐item Patient Health Questionnaire (PHQ‐9), and the 7‐item Generalized Anxiety Disorder Scale (GAD‐7) at baseline and 6‐ and 12‐month postimplantation.

Results

After excluding seven patients who experienced defibrillator shocks, we analyzed 99 patients (median age: 72 years, 77% men). The baseline MLHFQ score was 37 (interquartile range [IQR]: 36); at 6 months, 1 (IQR: 8); and at 12 months, 0.5 (IQR: 10); p < 0.01. The baseline PHQ‐9 score was 9 (IQR: 11); at 6 months, 0 (IQR: 2); and at 12 months, 0 (IQR: 2); p < 0.01. The baseline GAD‐7 score was 8 (IQR: 16); at 6 months, 0 (IQR: 1.5); and at 12 months, 0 (IQR: 3); p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnxietyHeart FailureDepressionCardiac Resynchronization Therapy DevicesCardiac Resynchronization TherapyHumansMaleFemaleAgedFollow-Up StudiesGreeceDefibrillators, Implantable

Stichwörter der Autor:innen

anxietycardiac resynchronization therapydepressionheart failurequality of life

Autor:innen und Institutionen

  • First Department of Cardiology, University of Ioannina Medical School, Ioannina, Greece.
  • Second Department of Cardiology, University of Ioannina Medical School, Ioannina, Greece.
  • First Division of Internal Medicine, University of Ioannina Medical School, Ioannina, Greece.
  • Department of Psychiatry, University of Ioannina Medical School, Ioannina, Greece.

Zitieren

APA

Florou, E., Sfairopoulos, D., Plakoutsi, S., Bechlioulis, A., Zekios, K., Milionis, H., Skapinakis, P., & Korantzopoulos, P. (2025). Depression and Anxiety in Patients Who Received a CRT Device and Did Not Have Shock Therapy During a 12‐Month Follow‐Up. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70002

Vancouver

Florou E, Sfairopoulos D, Plakoutsi S, Bechlioulis A, Zekios K, Milionis H, et al. Depression and Anxiety in Patients Who Received a CRT Device and Did Not Have Shock Therapy During a 12‐Month Follow‐Up. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70002

BibTeX
@article{Florou2025,
  author = {Florou, Elizabeth and Sfairopoulos, Dimitrios and Plakoutsi, Sofia and Bechlioulis, Aris and Zekios, Konstantinos and Milionis, Haralampos and Skapinakis, Petros and Korantzopoulos, Panagiotis},
  title = {Depression and Anxiety in Patients Who Received a CRT Device and Did Not Have Shock Therapy During a 12‐Month Follow‐Up},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.70002}
}
Kostenlos starten →