Comparing Efficacy and Complications Between Stylet‐Driven Leads and Lumenless Leads in Left Bundle Branch Area Pacing
Pacing and Clinical Electrophysiology · 2025
DOI: 10.1111/pace.15217 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Adivitch Sripusanapan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Pacemaker, Artificial, Bundle-Branch Block, Electrodes, Implanted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 75 Literaturangaben.
Abstract (Originalsprache)
Background
Left bundle branch area pacing (LBBAP) is an emerging technique in conduction system pacing (CSP) that may offer improved outcomes over traditional methods. Typically, lumenless leads are used; however, stylet‐driven leads have recently been considered. This study conducts a systematic review and meta‐analysis evaluating the efficacy and complications of stylet‐driven leads versus lumenless leads.
Method
Databases including PubMed, Embase, and Scopus were searched from inception to June 2024 for relevant studies. We included published prospective or retrospective randomized controlled trials and cohort studies using stylet‐driven leads or lumenless leads for LBBAP. Data were combined using a random‐effects, generic inverse variance method of DerSimonian and Laird.
Results
Sixty‐eight studies involving 8996 patients from 2016 to 2023 were included. From eight head‐to‐head studies, the stylet‐driven leads group had a comparable success rate (OR = 1.46, 95% CI: 0.89, 2.39) but showed shorter procedural time (weighted mean difference [WMD] = −16.82 min, 95% CI: −24.42, −9.21). Stylet‐driven leads had a higher pacing threshold at implantation (WMD = 0.09 V, 95% CI: 0.00, 0.17) and lower lead impedance (WMD = −86.13 ohms, 95% CI: −129.46, −42.80). QRS duration and R wave amplitude were comparable initially, but at follow‐up (1–12 months), stylet‐driven leads had a lower R wave amplitude (WMD = −1.92 mV, 95% CI: −3.33, −0.51). Complication rates were higher with stylet‐driven leads (OR = 1.80, 95% CI: 1.34, 2.41), particularly lead dislodgement (OR = 3.26, 95% CI: 1.75, 6.07) and helix damage (OR = 11.46, 95% CI: 3.58, 36.63).
Conclusion
In this meta‐analysis of 8996 patients, stylet‐driven leads for LBBAP showed a comparable success rate to lumenless leads but was associated with a higher complication risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
- Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
- Chulalongkorn University, Division of Cardiology, Department of Medicine, Bangkok, Thailand.
- Division of Cardiovascular Medicine, Center of Excellence in Arrhythmia Research, Cardiac Center, King Chulalongkorn Memorial Hospital, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
- Internal Medicine Residency Program, University of Hawaii, Honolulu, Hawaii, USA.
- Cardiac Arrhythmia Service, Massachusetts General Hospital, Harvard University, Boston, Massachusetts, USA.
ORCID-Profile: Adivitch Sripusanapan, Dingxin Qin, Pattara Rattanawong
Zitieren
APA
Sripusanapan, A., Wareesawetsuwan, N., Deepan, N., Yinadsawaphan, T., Qin, D., Rattanawong, P., & Ng, C. Y. (2025). Comparing Efficacy and Complications Between Stylet‐Driven Leads and Lumenless Leads in Left Bundle Branch Area Pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15217
Vancouver
Sripusanapan A, Wareesawetsuwan N, Deepan N, Yinadsawaphan T, Qin D, Rattanawong P, et al. Comparing Efficacy and Complications Between Stylet‐Driven Leads and Lumenless Leads in Left Bundle Branch Area Pacing. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.15217
BibTeX
@article{Sripusanapan2025,
author = {Sripusanapan, Adivitch and Wareesawetsuwan, Nicha and Deepan, Natee and Yinadsawaphan, Thanaboon and Qin, Dingxin and Rattanawong, Pattara and Ng, Chee Yuan},
title = {Comparing Efficacy and Complications Between Stylet‐Driven Leads and Lumenless Leads in Left Bundle Branch Area Pacing},
journal = {Pacing and Clinical Electrophysiology},
year = {2025},
doi = {10.1111/pace.15217}
}
EUVIMED