Pacing and Ablation Technique Using Microelectrode for Pulmonary Vein Isolation Using a Local Impedance‐Guided Catheter

Hitoshi Mori iD, Hidehira Fukaya iD, Kazuhisa Matsumoto, Masataka Narita, Tsukasa Naganuma, Wataru Sasaki, Naomichi Tanaka, Daisuke Kawano iD, Yoshifumi Ikeda iD, Kazuo Matsumoto, Ritsushi Kato

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.15144 ↗

At a glance

Übersichtsarbeit in Pacing and Clinical Electrophysiology, 2025. Written by Hitoshi Mori and 10 co-authors. Institution: Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan. Major MEDLINE topics: Pulmonary Veins, Catheter Ablation, Atrial Fibrillation, Cardiac Pacing, Artificial. Cited 1 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY-NC 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini‐electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.

Methods

Twenty‐seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter. The local impedance (LI) changes, generator impedance (GI) changes, and the time to capture loss were evaluated.

Results

First‐pass isolations were obtained in 15 patients (57.7 %) for right PVs and in 22 patients (84.6 %) for left PVs. At gap sites, the impedance decrease was smaller than at non‐gap sites (non‐gap sites vs. gap sites; LI drop, 23.2 [±10.3] vs. 15.6 [±7.7] Ω, p < 0.0001; GI drop, 4.8 [±4.1] vs. 2.7 [3.9] Ω, p = 0.0026; %LI drop, −19.3 [±7.4] vs. −13.1 [±6.1] %, p < 0.0001; % GI drop, −5.1 [±4.2] vs. −2.9 [±4.2] %, p = 0.0020), suggesting that changes in impedance could be useful for predicting gaps. The cutoff values for predicting no gaps were identified as 15.0 Ω for the LI drop and −13.74% for the %LI drop.

Conclusion

The LI showed greater changes than the GI and was also useful for predicting gaps. The cutoff values of 15.0 Ω for the LI drop and −13.74% for the %LI drop could predict conduction gaps. Under the monitoring of the LI, the pacing and ablation technique proved useful for PVI, even though the MiFi catheter does not have a CF sensor or ablation indices.

Subjects

MeSH terms (MEDLINE)

Pulmonary VeinsCatheter AblationAtrial FibrillationCardiac Pacing, ArtificialCardiac CathetersHumansMaleFemaleMiddle AgedMicroelectrodesElectric ImpedanceTreatment OutcomeEquipment DesignAged

Author keywords

IntellaNav MiFi OI catheteratrial fibrillationlocal impedancepacing and ablationradiofrequency ablation

Authors and institutions

  • Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
  • Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.

ORCID profiles: Hitoshi Mori, Hidehira Fukaya, Daisuke Kawano, Yoshifumi Ikeda

Cite

APA

Mori, H., Fukaya, H., Matsumoto, K., Narita, M., Naganuma, T., Sasaki, W., Tanaka, N., Kawano, D., Ikeda, Y., Matsumoto, K., & Kato, R. (2025). Pacing and Ablation Technique Using Microelectrode for Pulmonary Vein Isolation Using a Local Impedance‐Guided Catheter. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15144

Vancouver

Mori H, Fukaya H, Matsumoto K, Narita M, Naganuma T, Sasaki W, et al. Pacing and Ablation Technique Using Microelectrode for Pulmonary Vein Isolation Using a Local Impedance‐Guided Catheter. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.15144

BibTeX
@article{Mori2025,
  author = {Mori, Hitoshi and Fukaya, Hidehira and Matsumoto, Kazuhisa and Narita, Masataka and Naganuma, Tsukasa and Sasaki, Wataru and Tanaka, Naomichi and Kawano, Daisuke and Ikeda, Yoshifumi and Matsumoto, Kazuo and Kato, Ritsushi},
  title = {Pacing and Ablation Technique Using Microelectrode for Pulmonary Vein Isolation Using a Local Impedance‐Guided Catheter},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.15144}
}
Start for free →