Evolution of ventricular and valve function in patients with right ventricular pacing – A randomized controlled trial comparing leadless and conventional pacing
Pacing and Clinical Electrophysiology · 2023
DOI: 10.1111/pace.14870 ↗Kurz gefasst
Äquivalenzstudie in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Christophe Garweg und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium. Hauptthemen laut MEDLINE: Pacemaker, Artificial. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
Background
Leadless pacemakers (PMs) were recently introduced to overcome lead‐related complications. They showed high safety and efficacy profiles. Prospective studies assessing long‐term safety on cardiac structures are still missing.
Objective
The purpose of this study was to compare the mechanical impact of Micra with conventional PM on heart function.
Methods
We conducted a non‐inferiority trial in patients with an indication for single chamber ventricular pacing. Patients were 1:1 randomized to undergo implantation of either Micra or conventional monochamber ventricular pacemaker (PM). Patients underwent echocardiography at baseline, 6 and 12 months after implantation. Analysis included left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and valve function. N‐terminal‐pro hormone B‐type natriuretic peptide (NT‐pro‐BNP) levels were measured at baseline and 12 months.
Results
Fifty‐one patients (27 in Micra group and 24 in conventional group) were included. Baseline characteristics were similar for both groups. At 12 months, (1) the left ventricular function as assessed by LVEF and GLS worsened similarly in both groups (∆LVEF −10 ± 7.3% and ∆GLS +5.7 ± 6.4 in Micra group vs. −13.4 ± 9.9% and +5.2 ± 3.2 in conventional group) ( p = 0.218 and 0.778, respectively), (2) the severity of tricuspid valve regurgitation was significantly lower with Micra than conventional pacing ( p = 0.009) and (3) median NT‐pro‐BNP was lower in Micra group (970 pg/dL in Micra group versus 1394 pg/dL in conventional group, p = 0.041).
Conclusion
Micra is non inferior to conventional PMs concerning the evolution of left ventricular function at 12‐month follow‐up. Our data suggest that Micra has a comparable mechanical impact on the ventricular systolic function but resulted in less valvular dysfunction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
- Department of Cardiology, University Hospitals Leuven, Leuven, Belgium.
- Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.
ORCID-Profile: Christophe Garweg
Zitieren
APA
Garweg, C., Duchenne, J., Vandenberk, B., Mao, Y., Ector, J., Haemers, P., Poels, P., Voigt, J. U., & Willems, R. (2023). Evolution of ventricular and valve function in patients with right ventricular pacing – A randomized controlled trial comparing leadless and conventional pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14870
Vancouver
Garweg C, Duchenne J, Vandenberk B, Mao Y, Ector J, Haemers P, et al. Evolution of ventricular and valve function in patients with right ventricular pacing – A randomized controlled trial comparing leadless and conventional pacing. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14870
BibTeX
@article{Garweg2023,
author = {Garweg, Christophe and Duchenne, Jürgen and Vandenberk, Bert and Mao, Yankai and Ector, Joris and Haemers, Peter and Poels, Patricia and Voigt, Jens-Uwe and Willems, Rik},
title = {Evolution of ventricular and valve function in patients with right ventricular pacing – A randomized controlled trial comparing leadless and conventional pacing},
journal = {Pacing and Clinical Electrophysiology},
year = {2023},
doi = {10.1111/pace.14870}
}
EUVIMED