EUVIMEDDescoperă EUVIMED
Open access · CC BY-NC-ND 4.0

The QRS frontal plane axis changes during left bundle branch block after transcatheter aortic valve replacement

Oren Yagel, Bernard Belhassen iD, David Planer, Offer Amir, Gabby Elbaz-Greener

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14840 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Oren Yagel and 4 co-authors. Institution: Heart Institute, Hadassah Medical Center, Jerusalem, Israel. Major MEDLINE topics: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Atrioventricular Block. Cited 5 times so far (Crossref); 25 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Background and Aims Left bundle branch block (LBBB) is common after transcatheter aortic valve replacement (TAVR) and associated with a left or normal QRS axis. We aim to assess the QRS frontal plane axis shift changes during LBBB after TAVR and determine if the risk of procedure‐related high degree atrioventricular block (AVB) is affected by QRS axis shift changes. Methods and Results In a retrospective single‐center study of 720 consecutive patients who underwent TAVR, 141 (19.6%) with normal baseline QRS duration developed a new LBBB after TAVR and constituted the study group. Most patients (59.6%) were females and the mean age of the cohort was 81.2 ± 6 years.

Results

As compared with the baseline QRS axis before TAVR, the occurrence of LBBB was associated with a leftward QRS axis shift (by 40 ± 28.3°) in 73% of the study patients and a rightward (by 18.6 ± 19.4°) or no change in QRS axis in 25.6% and 1.4% of the study patients, respectively. A left QRS axis (−30°) was observed in 14.9% and 38.3% of the study patients before and after TAVR, respectively. The group of patients exhibiting a rightward or no QRS axis shift had a greater incidence of high degree AVB than the group of patients exhibiting a leftward QRS axis shift (18.4% vs. 6.8%, p = .056).

Conclusion

Although post TAVR‐LBBB is associated with a leftward QRS axis shift in most patients, a non‐negligible proportion of patients (27%) exhibited a rightward or no QRS axis shift. The latter group tend to have a higher risk of developing high degree AVB.

Subjects

MeSH terms (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisAtrioventricular BlockFemaleHumansAgedAged, 80 and overMaleBundle-Branch BlockTreatment OutcomeRetrospective StudiesElectrocardiographyArrhythmias, CardiacAortic Valve

Author keywords

QRS frontal axisatrioventricular blockleft axis deviationleft bundle branch blocktranscatheter aortic valve replacement

Authors and institutions

  • Heart Institute, Hadassah Medical Center, Jerusalem, Israel.
  • Hebrew University of Jerusalem, Jerusalem, Israel.
  • Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel.

ORCID profiles: Bernard Belhassen

Cite

APA

Yagel, O., Belhassen, B., Planer, D., Amir, O., & Elbaz-Greener, G. (2023). The QRS frontal plane axis changes during left bundle branch block after transcatheter aortic valve replacement. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14840

Vancouver

Yagel O, Belhassen B, Planer D, Amir O, Elbaz-Greener G. The QRS frontal plane axis changes during left bundle branch block after transcatheter aortic valve replacement. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14840

BibTeX
@article{Yagel2023,
  author = {Yagel, Oren and Belhassen, Bernard and Planer, David and Amir, Offer and Elbaz-Greener, Gabby},
  title = {The QRS frontal plane axis changes during left bundle branch block after transcatheter aortic valve replacement},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14840}
}
Start for free →