Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty
Pacing and Clinical Electrophysiology · 2024
DOI: 10.1111/pace.14803 ↗At a glance
Fallbericht in Pacing and Clinical Electrophysiology, 2024. Written by Erwin Ciechański and 6 co-authors. Institution: Department of Cardiology, Stefan Cardinal Wyszynski Regional Specialist Hospital, Lublin, Poland. Major MEDLINE topics: Prosthesis Implantation. 10 references.
Abstract (original language)
A 60‐year‐old female with heart failure with reduced left ventricle ejection fraction, implantable cardiac defibrillator and left bundle branch block was admitted to Department of Cardiology for cardiac resynchronization therapy defibrillator upgrade. Due to difficulties with advancement of left ventricular lead to lateral coronary vein, balloon angioplasty with use of retrograde approach via collateral branches and two CS sheaths positioning was performed. Final position of lead in lateral vein was achieved resulting with pacing threshold of 0.7 V/0.5 ms, impedance of 720 Ω and QRS of 130 ms.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Stefan Cardinal Wyszynski Regional Specialist Hospital, Lublin, Poland.
- Department of Toxicology, Medical University of Lublin, Lublin, Poland.
- Department of Gastroenterology, Stefan Cardinal Wyszynski Regional Specialist Hospital, Lublin, Poland.
- Department and Clinic of Cardiology, Medical University of Lublin, Lublin, Poland.
ORCID profiles: Erwin Ciechański, Piotr Denysiuk, Krystian Ciechański, Andrzej Głowniak
Cite
APA
Ciechański, E., Denysiuk, P., Ciechański, K., Chromiński, T., Szczasny, M., Błaszczak, P., & Głowniak, A. (2024). Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14803
Vancouver
Ciechański E, Denysiuk P, Ciechański K, Chromiński T, Szczasny M, Błaszczak P, et al. Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.14803
BibTeX
@article{Ciechaski2024,
author = {Ciechański, Erwin and Denysiuk, Piotr and Ciechański, Krystian and Chromiński, Tomasz and Szczasny, Marcin and Błaszczak, Piotr and Głowniak, Andrzej},
title = {Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty},
journal = {Pacing and Clinical Electrophysiology},
year = {2024},
doi = {10.1111/pace.14803}
}
EUVIMED