Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT)
Pacing and Clinical Electrophysiology · 2023
DOI: 10.1111/pace.14793 ↗At a glance
Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Chinmay Parale and 8 co-authors. Institution: Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India. Major MEDLINE topics: Cardiac Resynchronization Therapy. Cited 13 times so far (Crossref); 30 references.
Abstract (original language)
Background
In patients undergoing cardiac resynchronization therapy using left bundle branch area pacing (LBBP‐CRT), the addition of a coronary sinus lead, that is, Left bundle optimized CRT (LOT‐CRT) might confer additional benefits.
Objectives
To compare the electrocardiographic characteristics between LBBP‐CRT and LOT‐CRT Materials and Methods Patients with non‐ischemic cardiomyopathy (NICMP) and left bundle branch block (LBBB) with left ventricular ejection fraction 131 ms showed a significant reduction in QRSd with LOT‐CRT ( p = .03). QT interval was reduced with both modes of CRT. LOT‐CRT was associated with a greater reduction in QRS area ( p = .001), TpTe interval ( p = .03), and TpTe/QT ratio ( p = .013) compared to LBBP‐CRT.
Conclusions
In patients with NICMP and LBBB, there was no significant difference in QRSd with LOT‐CRT compared to LBBP‐CRT. However, in patients with QRSd > 131 ms after LBBP‐CRT, LOT‐CRT resulted in a significantly narrower QRS.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
ORCID profiles: Chinmay Parale, Dinakar Bootla, Ashish Jain
Cite
APA
Parale, C., Bootla, D., Jain, A., Satheesh, S., Anantharaj, A., Ahmed, A. S., Sukumaran, S. K., Balaguru, S., & Selvaraj, R. (2023). Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT). Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14793
Vancouver
Parale C, Bootla D, Jain A, Satheesh S, Anantharaj A, Ahmed AS, et al. Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT). Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14793
BibTeX
@article{Parale2023,
author = {Parale, Chinmay and Bootla, Dinakar and Jain, Ashish and Satheesh, Santhosh and Anantharaj, Avinash and Ahmed, A Shaheer and Sukumaran, Suresh Kumar and Balaguru, Sridhar and Selvaraj, Raja},
title = {Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT)},
journal = {Pacing and Clinical Electrophysiology},
year = {2023},
doi = {10.1111/pace.14793}
}
EUVIMED