EUVIMEDDescoperă EUVIMED
Crossref

Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT)

Chinmay Parale iD, Dinakar Bootla iD, Ashish Jain iD, Santhosh Satheesh, Avinash Anantharaj, A Shaheer Ahmed, Suresh Kumar Sukumaran, Sridhar Balaguru, Raja Selvaraj

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14793 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Chinmay Parale and 8 co-authors. Institution: Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India. Major MEDLINE topics: Cardiac Resynchronization Therapy. Cited 13 times so far (Crossref); 30 references.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Background

In patients undergoing cardiac resynchronization therapy using left bundle branch area pacing (LBBP‐CRT), the addition of a coronary sinus lead, that is, Left bundle optimized CRT (LOT‐CRT) might confer additional benefits.

Objectives

To compare the electrocardiographic characteristics between LBBP‐CRT and LOT‐CRT Materials and Methods Patients with non‐ischemic cardiomyopathy (NICMP) and left bundle branch block (LBBB) with left ventricular ejection fraction 131 ms showed a significant reduction in QRSd with LOT‐CRT ( p = .03). QT interval was reduced with both modes of CRT. LOT‐CRT was associated with a greater reduction in QRS area ( p = .001), TpTe interval ( p = .03), and TpTe/QT ratio ( p = .013) compared to LBBP‐CRT.

Conclusions

In patients with NICMP and LBBB, there was no significant difference in QRSd with LOT‐CRT compared to LBBP‐CRT. However, in patients with QRSd > 131 ms after LBBP‐CRT, LOT‐CRT resulted in a significantly narrower QRS.

Subjects

MeSH terms (MEDLINE)

Cardiac Resynchronization TherapyHumansStroke VolumeProspective StudiesVentricular Function, LeftTreatment OutcomeElectrocardiographyBundle-Branch BlockBundle of HisCardiac Pacing, Artificial

Author keywords

cardiac resynchronization therapyconduction system pacingelectrocardiographyleft bundle area pacing

Authors and institutions

  • Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.

ORCID profiles: Chinmay Parale, Dinakar Bootla, Ashish Jain

Cite

APA

Parale, C., Bootla, D., Jain, A., Satheesh, S., Anantharaj, A., Ahmed, A. S., Sukumaran, S. K., Balaguru, S., & Selvaraj, R. (2023). Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT). Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14793

Vancouver

Parale C, Bootla D, Jain A, Satheesh S, Anantharaj A, Ahmed AS, et al. Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT). Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14793

BibTeX
@article{Parale2023,
  author = {Parale, Chinmay and Bootla, Dinakar and Jain, Ashish and Satheesh, Santhosh and Anantharaj, Avinash and Ahmed, A Shaheer and Sukumaran, Suresh Kumar and Balaguru, Sridhar and Selvaraj, Raja},
  title = {Comparison of electrocardiographic parameters between left bundle optimized cardiac resynchronization therapy (LOT‐CRT) and left bundle branch pacing—cardiac resynchronization therapy (LBBP‐CRT)},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14793}
}
Start for free →