Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Ahmed El Damaty and 8 co-authors. Institution: Department of Cardiovascular Medicine, Electrophysiology and Pacing Service, Cairo University, Cairo, Egypt. Major MEDLINE topics: Tachycardia, Ectopic Atrial, Catheter Ablation. 13 references.
Abstract (original language)
Background
Surface ECG is a useful tool to guide mapping of focal atrial tachycardia (AT).
Objectives
We aimed to construct 12‐lead ECG templates for P‐wave morphology (PWM) during endocardial pacing from different sites in both atria in patients with no apparent structural heart disease (derivation cohort), with the goal of creating a localization algorithm, which could subsequently be validated in a cohort of patients undergoing catheter ablation of focal AT (validation cohort).
Methods
We prospectively enrolled consecutive patients who underwent electrophysiology study, had no structural heart disease and no atrial enlargement. Atrial pacing, at twice diastolic threshold, was carried out at different anatomical sites in both atria. Paced PWM and duration were assessed. An algorithm was generated from the constructed templates of each pacing site. The algorithm was applied on a retrospective series of successfully ablated AT patients. Overall and site‐specific accuracy were determined.
Results
Derivation cohort included 65 patients (25 men, age 37 ± 13 years). Atrial pacing was performed in 1025 sites in 61 patients (95%) in RA and in 15 patients (23%) in LA. The validation cohort included 71 patients (28 men, age 52 ± 19 years). AT were right atrial in 66.2%. The algorithm successfully predicted AT origin in 91.5% of patients (100% in LA and 87.2% in RA). It was off by one adjacent segment in the remaining 8.5%.
Conclusions
A simple ECG algorithm based on paced PWM templates was highly accurate in localizing site of origin of focal AT in patients with structurally normal hearts.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiovascular Medicine, Electrophysiology and Pacing Service, Cairo University, Cairo, Egypt.
- QE II Health Sciences Center, Division of Cardiology, Heart Rhythm Service, Halifax, Nova Scotia, Canada.
ORCID profiles: Ahmed El Damaty, Mahmoud El-Mowafy
Cite
APA
Damaty, A. E., Yahya, D., El-Mowafy, M., Rizk, H., Sapp, J., Parkash, R., Gardner, M., Gray, C., & AbdelWahab, A. (2023). Paced P‐wave morphology templates to guide atrial tachycardia localization: A derivation and validation study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14774
Vancouver
Damaty AE, Yahya D, El-Mowafy M, Rizk H, Sapp J, Parkash R, et al. Paced P‐wave morphology templates to guide atrial tachycardia localization: A derivation and validation study. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14774
BibTeX
@article{Damaty2023,
author = {Damaty, Ahmed El and Yahya, Dhaifallah and El-Mowafy, Mahmoud and Rizk, Hussien and Sapp, John and Parkash, Ratika and Gardner, Martin and Gray, Chris and AbdelWahab, Amir},
title = {Paced P‐wave morphology templates to guide atrial tachycardia localization: A derivation and validation study},
journal = {Pacing and Clinical Electrophysiology},
year = {2023},
doi = {10.1111/pace.14774}
}
EUVIMED