Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Arash Aryana and 12 co-authors. Institution: Department of Cardiology and Cardiovascular Surgery, Mercy General Hospital and Dignity Health Heart and Vascular Institute, Sacramento, California, …. Major MEDLINE topics: Atrial Fibrillation, Pulmonary Veins, Cryosurgery, Catheter Ablation. Cited 1 times so far (Crossref); 35 references.
Abstract (original language)
Background
Although pulmonary vein isolation (PVI) remains the cornerstone of catheter ablation of atrial fibrillation (AF), several studies have illustrated clinical benefits associated with PVI with posterior wall isolation (PWI).
Methods
This retrospective study investigated the outcomes of PVI alone versus PVI+PWI performed using the cryoballoon in patients with cardiac implantable electronic devices (CIEDs) and paroxysmal AF (PAF) or persistent AF (PersAF).
Results
Acute PVI was achieved in all patients using cryoballoon ablation. Compared to PVI alone, PVI+PWI was associated with longer cryoablation, fluoroscopy, and total procedure times. Adjunct radiofrequency was required to complete PWI in 29/77 patients (37.7%). Adverse events were similar with PVI alone versus PVI+PWI. But at 24 ± 7 months of follow‐up, not only cryoballoon PVI+PWI was associated with improved freedom from recurrent AF (74.3% vs. 46.0%, P = .007) and all atrial tachyarrhythmias (71.4% vs. 38.1%, P = .001) in patients with PersAF, cryoballoon PVI+PWI also yielded greater freedom from AF (88.1% vs. 63.7%, P = .003) and all atrial tachyarrhythmias (83.3% vs. 60.8%, P = .008) in those with PAF. Additionally, PVI+PWI was associated with higher reductions in atrial tachyarrhythmia burden (97.9% vs. 91.6%, P < .001), need for cardioversion (5.2% vs. 23.6%, P < .001) and repeat catheter ablation (10.4% vs. 26.1%, P = .005), and a longer time‐to‐arrhythmia recurrence (16 ± 6 months vs. 8 ± 5 months, P < .001) in both PersAF and PAF patients.
Conclusion
In CIED patients with PersAF or PAF, cryoballoon PVI+PWI is associated with a greater freedom from recurrent AF and atrial tachyarrhythmias, as compared to PVI alone during long‐term follow‐up.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology and Cardiovascular Surgery, Mercy General Hospital and Dignity Health Heart and Vascular Institute, Sacramento, California, USA.
- California Northstate University College of Medicine, Elk Grove, California, USA.
- University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.
- Sutter Heart and Vascular Institute, Sacramento, California, USA.
- Overlake Hospital Medical Center, Bellevue, Washington, USA.
- University of Colorado Health, Fort Collins, Aurora, Colorado, USA.
ORCID profiles: Arash Aryana
Cite
APA
Aryana, A., Thiemann, A. M., Pujara, D. K., Cossette, L. L., Allen, S. L., Vierra, E. C., Bowers, M. R., Gandhavadi, M., Heath, R., Trivedi, A. D., O'Neill, P. G., Ellis, E. R., & d'Avila, A. (2023). Outcomes of adjunct posterior wall isolation in atrial fibrillation patients with cardiac implantable electronic devices. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14767
Vancouver
Aryana A, Thiemann AM, Pujara DK, Cossette LL, Allen SL, Vierra EC, et al. Outcomes of adjunct posterior wall isolation in atrial fibrillation patients with cardiac implantable electronic devices. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14767
BibTeX
@article{Aryana2023,
author = {Aryana, Arash and Thiemann, Anna M and Pujara, Deep K and Cossette, Laura L and Allen, Shelley L and Vierra, Eleanor C and Bowers, Mark R and Gandhavadi, Maheer and Heath, Russell and Trivedi, Amar D and O'Neill, Padraig Gearoid and Ellis, Ethan R and d'Avila, André},
title = {Outcomes of adjunct posterior wall isolation in atrial fibrillation patients with cardiac implantable electronic devices},
journal = {Pacing and Clinical Electrophysiology},
year = {2023},
doi = {10.1111/pace.14767}
}
EUVIMED