EUVIMEDSkopri EUVIMED
Multizentrische StudieOpen access · CC BY-NC 4.0

Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses

Tom de Potter, Andrea Sarkozy, Mattias Duytschaever, Alan Bulava

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14708 ↗

At a glance

Multizentrische Studie in Pacing and Clinical Electrophysiology, 2023. Written by Tom de Potter and 3 co-authors. Institution: Cardiology Department, OLV Hospital, Aalst, Belgium. Major MEDLINE topics: Atrial Fibrillation, Tachycardia, Supraventricular, Catheter Ablation, Pulmonary Veins. Cited 3 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC 4.0).

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

The study is intended to evaluate the acute and long‐term effectiveness and peri‐procedural safety in ablation of persistent atrial fibrillation (PsAF) using the CartoFinder algorithm guided ablation (CFGA) targeting on repetitive activation patterns (RAPs) and focal impulses (FIs) identified in dynamic maps.

Methods

This is a prospective, single‐arm, multicenter study. A 64‐pole multielectrode basket catheter was used for intracardiac global electrogram (EGM) mapping. The RAPs or FIs were repeatedly mapped and ablated for up to five iterations by the CartoFinder algorithm to achieve sinus rhythm (SR) or organized atrial tachycardia (AT), which were followed by PVI. All patients were followed up for 12 months after procedure.

Results

Sixty‐four PsAF patients (age, 60.7 ± 9.1 years; male, 76.6%; median PsAF duration, 6.0 months) underwent CFGA on RAPs/FIs. Six patients (9.4%) reported primary adverse event (PAE) including groin hematoma (2), complete heart block (1), tamponade (1), pericarditis (1), and pseudoaneurysm (1). Repeated mapping and ablation on RAPs/FIs resulted in the cycle length (CL) increase from 191.0 ± 167.6 ms at baseline to 365.7 ± 296.7 ms in the LA and from 167.8 ± 41.6 ms to 379.4 ± 293.5 ms in the RA and 30.2% (19/63) AF termination to SR or organized AT. The 12‐month arrhythmia‐free and symptomatic AF‐free rates were 60.9% and 75.0%, respectively. Patients with acute AF termination showed a higher 12‐month arrhythmia‐free rate (76.9%) than those without (50.0%, p = .04).

Conclusions

The study demonstrated that the CartoFinder algorithm can be used for global activation mapping during PsAF ablation. Patients with acute AF termination had a lower 12‐month AF recurrence rate compared to patients without.

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationTachycardia, SupraventricularCatheter AblationPulmonary VeinsHumansMaleMiddle AgedAgedProspective StudiesTreatment OutcomeRecurrence

Author keywords

ablationfocal impulsemapping systempersistent atrial fibrillationrepetitive activation pattern

Authors and institutions

  • Cardiology Department, OLV Hospital, Aalst, Belgium.
  • Cardiology Department, Universitair Ziekenhuis Antwerpen, Edegem, Belgium.
  • University of Antwerp, Antwerpen, Belgium.
  • Cardiology Department, AZ Sint Jan, Bruges, Belgium.
  • Ceske Budejovice Hospital, Ceske Budejovice, Czech Republic.
  • Faculty of Health and Social Sciences, University of South Bohemia in Ceske Budejovice, Ceske Budejovice, Czech Republic.

Cite

APA

de Potter, T., Sarkozy, A., Duytschaever, M., & Bulava, A. (2023). Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14708

Vancouver

de Potter T, Sarkozy A, Duytschaever M, Bulava A. Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14708

BibTeX
@article{dePotter2023,
  author = {de Potter, Tom and Sarkozy, Andrea and Duytschaever, Mattias and Bulava, Alan},
  title = {Safety and efficacy of catheter ablation on patients with persistent atrial fibrillation by targeting repetitive activation patterns and focal impulses},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14708}
}
Start for free →