EUVIMEDTutustu EUVIMEDiin
Open access · CC BY-NC 4.0

Reduced inferior wall longitudinal strain is associated with malignant arrhythmias in non‐ischemic heart failure

Ulrik Winsløw iD, Marie Bayer Elming, Jens Jakob Thune, Jens Haarbo, Berit Thornvig Philbert, Jesper Hastrup Svendsen, Steen Pehrson, Christian Jøns, Henning Bundgaard, Lars Køber, Niels Risum

Pacing and Clinical Electrophysiology · 2023-07 · 46 (7) · 721-728

DOI: 10.1111/pace.14706 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, published online on 2023-04-30. Written by Ulrik Winsløw and 10 co-authors. Institution: Department of Cardiology, Copenhagen University, Hospital-Rigshospitalet, Copenhagen, Denmark. Major MEDLINE topics: Defibrillators, Implantable, Heart Failure, Ventricular Dysfunction, Left. Cited 4 times so far (Crossref); 25 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Medtronic, St Jude Medical, TrygFonden, and the Danish Heart Foundation.

TiivistelmäSubjectsBibliografiset tiedotCiteRelated studies

Abstract (original language)

Background

Reduced systolic myocardial function in the inferior region of the left ventricle has been suggested to be associated with malignant arrhythmias. We tested this hypothesis in patients with non‐ischemic heart failure.

Methods

Patients with non‐ischemic heart failure (left ventricular ejection fraction [LVEF] < 35%) were evaluated by 2D‐speckle‐tracking echocardiography. The regional longitudinal strain was calculated for each of the six left ventricular walls. The reduced regional function was defined as strain below the median. The outcome was a composite of sudden cardiac death, admission with sustained ventricular arrhythmia, resuscitated cardiac arrest, and appropriate therapy from a primary prophylactic implantable cardioverter defibrillator. Time‐to‐first‐event analysis was performed using a Cox model.

Results

From two centers, 401 patients were included (median age: 63 years, 72% male) with a median LVEF of 25% (interquartile range [IQR] 20;30), and a median inferior wall strain of –9.0% (–12.5; –5.4). During a median follow‐up of 4.0 years, 52 outcomes occurred. After multivariate adjustment for clinical and electrocardiographic parameters, inferior wall strain was independently associated with the outcome (HR 2.50 [1.35; 4.62], p = .003). No independent association was found between the composite outcome and reduced strain in any of the other left ventricular walls, Global Longitudinal Strain (HR 1.66 [0.93; 2.98], p = .09), or LVEF (HR 1.33 [0.75; 2.33], p = .33).

Conclusions

Below median strain in the left ventricular inferior region was independently associated with a 2.5‐fold increase in the risk of malignant arrhythmias and sudden cardiac death in patients with non‐ischemic heart failure.

Subjects

MeSH terms (MEDLINE)

Defibrillators, ImplantableHeart FailureVentricular Dysfunction, LeftHumansMaleMiddle AgedFemaleVentricular Function, LeftStroke VolumeRisk FactorsPredictive Value of TestsArrhythmias, CardiacDeath, Sudden, Cardiac

Author keywords

global longitudinal strainimplantable cardioverter-defibrillatorleft ventricular ejection fractionmechanical deformationmyocardial strainregional deformationsudden cardiac deathventricular arrhythmia

Authors and institutions

  • Department of Cardiology, Copenhagen University, Hospital-Rigshospitalet, Copenhagen, Denmark.
  • Department of Cardiology, Zealand University Hospital-Roskilde, Roskilde, Denmark.
  • Department of Cardiology, Copenhagen University Hospital-Bispebjerg and Frederiksberg, Copenhagen, Denmark.
  • Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
  • Department of Cardiology, Copenhagen University Hospital-Herlev and Gentofte, Herlev, Denmark.

ORCID profiles: Ulrik Winsløw

Funding

  • Medtronic, St Jude Medical, TrygFonden, and the Danish Heart Foundation

Cite

APA

Winsløw, U., Elming, M. B., Thune, J. J., Haarbo, J., Thornvig Philbert, B., Svendsen, J. H., Pehrson, S., Jøns, C., Bundgaard, H., Køber, L., & Risum, N. (2023). Reduced inferior wall longitudinal strain is associated with malignant arrhythmias in non‐ischemic heart failure. Pacing and Clinical Electrophysiology, 46(7), 721-728. https://doi.org/10.1111/pace.14706

Vancouver

Winsløw U, Elming MB, Thune JJ, Haarbo J, Thornvig Philbert B, Svendsen JH, et al. Reduced inferior wall longitudinal strain is associated with malignant arrhythmias in non‐ischemic heart failure. Pacing and Clinical Electrophysiology. 2023;46(7):721-728. doi:10.1111/pace.14706

BibTeX
@article{Winslw2023,
  author = {Winsløw, Ulrik and Elming, Marie Bayer and Thune, Jens Jakob and Haarbo, Jens and Thornvig Philbert, Berit and Svendsen, Jesper Hastrup and Pehrson, Steen and Jøns, Christian and Bundgaard, Henning and Køber, Lars and Risum, Niels},
  title = {Reduced inferior wall longitudinal strain is associated with malignant arrhythmias in non‐ischemic heart failure},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  volume = {46},
  number = {7},
  pages = {721--728},
  doi = {10.1111/pace.14706}
}
Start for free →