Quality of life of children and young adults with and without cardiovascular implantable electronic devices during the COVID‐19 pandemic

Joseph Solomon Needleman iD, Chengjia Zhu, Adam C Kean iD

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14677 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Joseph Solomon Needleman and 2 co-authors. Institution: Internal Medicine-Pediatrics Residency Program, Indiana University School of Medicine, Indianapolis, Indiana, USA. Major MEDLINE topics: Defibrillators, Implantable, Pacemaker, Artificial, COVID-19. Cited 3 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Children with cardiovascular implantable electronic devices (CIEDs) have a lower quality of life (QoL) compared to the general pediatric population. The combined effect of COVID‐19 and CIEDs on the QoL and physical activity (PA) both within and between each population is unknown.

Methods

Individuals 8–25‐year‐old with and without CIED's were recruited to complete a phone survey. Data collection included demographics, the Pediatric Quality of Life Inventory (PedsQL), and the (PAQ). PedsQL and PAQ scores range from 0–100 and 1–5, respectively, with higher scores indicating a higher QoL and PA.

Results

Of the 190 individuals contacted, 148 participated (CIED n = 76, non‐CIED n = 72), for an 81% response rate. Participants with and without CIEDs were similar in age (15.5 vs. 16 years, p = .57), gender (male = 57% vs. 42%, p = .07), and self‐identified race (white = 79% vs. 81%, p = .44). CIED participants had a lower QoL (70.8 vs. 83.3, p < .001). Lower total scores were noted in CIED participants with structural heart disease compared to those without (71.6 vs. 83.6, p = .035) and those with a history of non‐CIED heart or chest surgery compared to those without (71.3 vs. 83.3, p = .035). PAQ scores were similarly lower for CIED participants (2.17 vs. 2.73, p < .001).

Conclusion

The presence of a CIED negatively impacts the QoL and PA of the pediatric population in the setting of the COVID‐19 pandemic. Further research is needed to better understand and address the drivers of decreased QoL and PA in the pediatric CIED population in the setting of the COVID‐19 Pandemic.

Subjects

MeSH terms (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialCOVID-19HumansMaleChildYoung AdultAdolescentAdultQuality of LifePandemics

Author keywords

COVID-19defibrillatorpacemakerpediatricphysical activityquality of lifeyoung adult

Authors and institutions

  • Internal Medicine-Pediatrics Residency Program, Indiana University School of Medicine, Indianapolis, Indiana, USA.
  • Family Medicine Residency Program, University of Calgary, Calgary, Alberta, Canada.
  • Pediatric Electrophysiology, Division of Pediatric Cardiology, Department of Pediatrics, Indiana University School of Medicine, Indianapolis, Indiana, USA.

ORCID profiles: Joseph Solomon Needleman, Adam C Kean

Cite

APA

Needleman, J. S., Zhu, C., & Kean, A. C. (2023). Quality of life of children and young adults with and without cardiovascular implantable electronic devices during the COVID‐19 pandemic. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14677

Vancouver

Needleman JS, Zhu C, Kean AC. Quality of life of children and young adults with and without cardiovascular implantable electronic devices during the COVID‐19 pandemic. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14677

BibTeX
@article{Needleman2023,
  author = {Needleman, Joseph Solomon and Zhu, Chengjia and Kean, Adam C},
  title = {Quality of life of children and young adults with and without cardiovascular implantable electronic devices during the COVID‐19 pandemic},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14677}
}
Start for free →