EUVIMEDSkopri EUVIMED
Open access · CC BY-NC-ND 4.0

Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization

Peng Song, Shuangyin He, Tao Chen, Han Chen, Wenfu Yang, Xiyuan Tang, Tingting Xu, Xiaohong Yin, Bo Tan iD

Orthopaedic Surgery · 2026

DOI: 10.1111/os.70402 ↗

At a glance

Journal article in Orthopaedic Surgery, 2026. Written by Peng Song and 8 co-authors. Institution: Department of Neurosurgery, Guangyuan Central Hospital, Guangyuan, China. Major MEDLINE topics: Spinal Fusion, Vertebral Artery, Pedicle Screws, Atlanto-Axial Joint. 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Health Commission of Sichuan Province Medical Science and Technology Program, Wu Jieping Medical Foundation, Sichuan Provincial Regional Medical Center for Neurological Diseases Construction Program.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Although C2 pedicle screws are considered the gold standard for atlantoaxial fixation, the optimal fixation strategy for patients with high‐riding vertebral arteries (HRVA) or narrow C2 pedicles (NC2P) remains controversial because of the increased risk of vertebral artery injury and the limitations of alternative fixation techniques.

Objective

To evaluate the safety, stability, and clinical efficacy of an individualized C2 screw fixation strategy incorporating vertebral artery mobilization for complex upper cervical anatomy.

Methods

A retrospective study was conducted in 312 patients who underwent C2 fixation between 2017 and 2025. Patients were categorized according to fusion method, screw laterality, and VA transposition requirement. Bone fusion rates and screw accuracy (Gertzbein–Robbins grading) were compared across groups using χ 2 , Fisher's exact, and multivariate logistic regression analyses to control confounders.

Results

All procedures were successfully completed without permanent neurovascular injury. At 6 months, the fusion rate with an atlantoaxial fusion cage was significantly higher than with interlaminar bone grafting (92.3% vs. 51.0%, p < 0.001). Unilateral C2 pedicle screw fixation combined with a contralateral alternative screw achieved comparable stability to bilateral fixation ( p > 0.05). Screw placement accuracy was 100% clinically acceptable in normal anatomy and 60% in cases requiring VA mobilization, with no VA injury or blood flow compromise.

Conclusion

The proposed multi‐strategy C2 screw placement protocol—integrating fusion cage support and VA mobilization—achieves superior fusion, reliable fixation, and high safety, even in anatomically challenging conditions. This approach provides a reproducible and versatile solution for C2 instrumentation in complex craniovertebral junction surgery.

Subjects

MeSH terms (MEDLINE)

Spinal FusionVertebral ArteryPedicle ScrewsAtlanto-Axial JointCervical VertebraeHumansRetrospective StudiesFemaleMaleMiddle AgedAdultAged

Author keywords

C2 pedicle screwatlantoaxial fixationcraniovertebral junctionhigh‐riding vertebral arteryscrew placement accuracyvertebral artery transposition

Authors and institutions

  • Department of Neurosurgery, Guangyuan Central Hospital, Guangyuan, China.

ORCID profiles: Bo Tan

Funding

  • Health Commission of Sichuan Province Medical Science and Technology Program
  • Wu Jieping Medical Foundation
  • Sichuan Provincial Regional Medical Center for Neurological Diseases Construction Program

Cite

APA

Song, P., He, S., Chen, T., Chen, H., Yang, W., Tang, X., Xu, T., Yin, X., & Tan, B. (2026). Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization. Orthopaedic Surgery. https://doi.org/10.1111/os.70402

Vancouver

Song P, He S, Chen T, Chen H, Yang W, Tang X, et al. Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization. Orthopaedic Surgery. 2026. doi:10.1111/os.70402

BibTeX
@article{Song2026,
  author = {Song, Peng and He, Shuangyin and Chen, Tao and Chen, Han and Yang, Wenfu and Tang, Xiyuan and Xu, Tingting and Yin, Xiaohong and Tan, Bo},
  title = {Safety and Stability of a Combined C2 Screw Placement Strategy With Vertebral Artery Mobilization},
  journal = {Orthopaedic Surgery},
  year = {2026},
  doi = {10.1111/os.70402}
}
Start for free →