Distal Femoral Interlocking Screw Length Can be Estimated Using “Anatomic Zones” During Femoral Intramedullary Nailing
Orthopaedic Surgery · 2026
DOI: 10.1111/os.70401 ↗At a glance
Journal article in Orthopaedic Surgery, 2026. Written by Douglas Zhang and 4 co-authors. Institution: Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA. Major MEDLINE topics: Fracture Fixation, Intramedullary, Bone Screws, Femoral Fractures, Femur. 29 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Objective
Depth‐gauge measurements can be time‐consuming and prone to technical error. The aim of this study is to evaluate whether “anatomic zones” along the distal femur can be used to help estimate distal interlocking screw length during femoral intramedullary nailing.
Methods
A retrospective “anatomical control” cohort was used to establish anatomic zones along the length of the distal femur and estimated screw length within each zone. Estimated screw lengths for each zone were based on mean cortex‐to‐cortex length at each zone as measured on computed tomography (CT). A validation cohort was prospectively enrolled to evaluate agreement between these estimated screw lengths and depth‐gauge measurements for each zone. Agreement was evaluated using mean differences between estimated screw lengths and depth‐gauge measurements, an intraclass correlation coefficient (ICC), and Bland–Altman analysis.
Results
The retrospective cohort of 56 patients was used to establish eight anatomic zones. Screw length estimates derived from CT‐based measurements ranged between 42.1 mm in the most proximal zone to 80.2 mm in the most distal zone. The validation cohort included 74 patients (126 screws), was 63.51% male ( n = 47), with mean age 44.2 ± 24.7 years, mean height 173.2 ± 12.7 cm, and mean BMI 28.5 ± 10 kg/m 2 . The mean absolute value difference between zone‐estimated screw lengths and depth‐gauge measurements was 3.9 mm ±2.9 mm, ranging 2.7 mm‐5.6 mm depending on zone. The ICC was 0.94 (95% CI [0.91, 0.96], p < 0.01). Bland–Altman analysis revealed a bias of −0.86 mm with limits of agreement at +8.6 mm and −10.3 mm.
Conclusion
Anatomic zone‐based screw length estimates derived from CT data show strong agreement with depth‐gauge measurements and are a potential adjunctive strategy to reduce operative time and errors in screw length selection without the need for additional equipment or technology.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA.
- Hospital for Special Surgery, New York, New York, USA.
- Department of Orthopaedic Surgery and Rehabilitation Medicine, University of Chicago, Chicago, Illinois, USA.
- Department of Orthopaedic Surgery, Washington University School of Medicine, Saint Louis, Missouri, USA.
ORCID profiles: Douglas Zhang, Mary Kate Erdman, Anthony V Christiano, Jason Strelzow
Cite
APA
Zhang, D., Baker, H. P., Erdman, M. K., Christiano, A. V., & Strelzow, J. (2026). Distal Femoral Interlocking Screw Length Can be Estimated Using “Anatomic Zones” During Femoral Intramedullary Nailing. Orthopaedic Surgery. https://doi.org/10.1111/os.70401
Vancouver
Zhang D, Baker HP, Erdman MK, Christiano AV, Strelzow J. Distal Femoral Interlocking Screw Length Can be Estimated Using “Anatomic Zones” During Femoral Intramedullary Nailing. Orthopaedic Surgery. 2026. doi:10.1111/os.70401
BibTeX
@article{Zhang2026,
author = {Zhang, Douglas and Baker, Hayden P and Erdman, Mary Kate and Christiano, Anthony V and Strelzow, Jason},
title = {Distal Femoral Interlocking Screw Length Can be Estimated Using “Anatomic Zones” During Femoral Intramedullary Nailing},
journal = {Orthopaedic Surgery},
year = {2026},
doi = {10.1111/os.70401}
}
EUVIMED