Exploring the Effectiveness of “Four‐Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults
Orthopaedic Surgery · 2026-08 · 18 (8) · 1734-1752
DOI: 10.1111/os.70377 ↗At a glance
Studienprotokoll in Orthopaedic Surgery, published online on 2026-07-17. Written by Yujie Li and 4 co-authors. Institution: Department of Joint Surgery, People's Hospital of Leshan, Leshan, China. Major MEDLINE topics: Femoral Neck Fractures, Fracture Fixation, Internal, Bone Screws. 62 references. The full text is freely available (open access, CC BY 4.0). Funded by: the Special scientific research project of Sichuan Provincial Medical Science and Technology Innovation Research Association, the Natural Science Foundation of Sichuan Province, the Southwest Medical University university-level project.
Abstract (original language)
Background
Pauwels type III femoral neck fractures (P3FNFs) are one of the common types of femoral neck fractures (FNF) caused by high‐energy violent factors. This study aims to evaluate the efficacy of inverted cannulated cancellous screw (ICCS) assisted transversal cannulated screw (TCS) perpendicular to the fracture line in young adults with Pauwels type III femoral neck fractures.
Methods
Construct an internal fixation‐fracture model through finite element analysis (FEA) and biomechanical test (BT) to simulate the stress environment of the human hip joint, and utilize the femoral neck system (FNS) model as a control to predict the biomechanical properties of ICCS + TCS. From January 2023 to December 2024, 21 patients with P3FNFs treated with ICCS + TCS were collected, and their recent radiographic and clinical outcomes were evaluated. The experimental data underwent statistical analysis using one‐way ANOVA and independent samples t ‐test.
Result
ICCS + TCS exhibits biomechanical trends in FEA and BT that are essentially consistent with those of FNS. ICCS + TCS has stronger torsional stiffness and lower overall deformation, But the resistance to vertical shear force is weaker than FNS. All patients in this study successfully completed the surgery without complications such as vascular or nerve injuries. The follow‐up period ranged from 8 to 25 months. The hip joint flexion‐extension ROM, internal–external rotation ROM, and Harris score all significantly increased ( p < 0.05). The shortening length of the femoral neck was 3.87 ± 0.44 mm.
Conclusion
ICCS + TCS exhibits biomechanical trends compared to FNS; meanwhile, it has stronger torsional resistance and load‐bearing deformations. Simultaneously, ICCS + TCS has demonstrated favorable outcomes in clinical treatments. This study offers a novel approach for the treatment of P3FNFs.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Joint Surgery, People's Hospital of Leshan, Leshan, China.
- Department of Orthopedics, Affiliated Hospital, Southwest Medical University, Luzhou, China.
ORCID profiles: Yujie Li, Naiqiang Zhuo
Funding
- the Special scientific research project of Sichuan Provincial Medical Science and Technology Innovation Research Association
- the Natural Science Foundation of Sichuan Province
- the Southwest Medical University university-level project
- the Luzhou-Southwest Medical University Joint Proiect
Cite
APA
Li, Y., Wen, Z., Jian, Z., Zhuo, N., & Shen, S. (2026). Exploring the Effectiveness of “Four‐Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults. Orthopaedic Surgery, 18(8), 1734-1752. https://doi.org/10.1111/os.70377
Vancouver
Li Y, Wen Z, Jian Z, Zhuo N, Shen S. Exploring the Effectiveness of “Four‐Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults. Orthopaedic Surgery. 2026;18(8):1734-1752. doi:10.1111/os.70377
BibTeX
@article{Li2026,
author = {Li, Yujie and Wen, Zhenyu and Jian, Zhang and Zhuo, Naiqiang and Shen, Shi},
title = {Exploring the Effectiveness of “Four‐Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults},
journal = {Orthopaedic Surgery},
year = {2026},
volume = {18},
number = {8},
pages = {1734--1752},
doi = {10.1111/os.70377}
}
EUVIMED