EUVIMEDDescubrir EUVIMED
Open access · CC BY 4.0

Temporal Evolution and Stationary Point Mechanisms of Pelvic Characteristic Angles Throughout the Sit‐to‐Stand Cycle

Houwen Zheng, Chen-Xu Liu, Haoyue Xin, Hua Tian iD, Zhanli Liu, Minwei Zhao

Orthopaedic Surgery · 2026-08 · 18 (8) · 1688-1699

DOI: 10.1111/os.70366 ↗

At a glance

Journal article in Orthopaedic Surgery, published online on 2026-07-08. Written by Houwen Zheng and 5 co-authors. Institution: Department of Engineering Mechanics, Applied Mechanics Lab, School of Aerospace, Tsinghua University, Beijing, China. Major MEDLINE topics: Pelvis, Pelvic Bones, Standing Position, Sitting Position. 42 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Natural Science Foundation of China.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Objectives

Prosthetic impingement and dislocation remain prevalent complications following total hip arthroplasty (THA). The “safe zone” concept guiding acetabular component placement is predicated on static body positions, while neglecting the kinematic changes in pelvic angles throughout the stand‐to‐sit (STS) transition cycle. This static‐centric approach constitutes a primary contributing factor to THA‐related complications. Consequently, investigating the kinematic regularity of pelvic motion across the entire STS cycle is of particular significance for optimizing surgical strategies and improving postoperative outcomes.

Methods

Dynamic pelvic angles are analyzed in 10 healthy individuals performing STS using optical motion capture combined with biodynamics simulations. The skeletal model is scaled to each subject, and inverse kinematics is used to compute motion trajectories, from which the time‐varying characteristics of sacral slope (SS), pelvic incidence (PI), and pelvic tilt (PT) angles are extracted.

Results

The skeletal model of the STS movement cycle is simulated, revealing the nonlinear variations in pelvic characteristic angles. Notably, the variation curves of SS and PT angles both exhibit distinct stationary points during the critical phase of the movement cycle, with the two parameters showing opposite changing trends. Specifically, PT angle decreases sharply to a trough within the 44.48%–53.19% interval of the movement cycle and then gradually rebounds from this stationary point. In contrast, SS angle increases first and then decreases, with its stationary point highly coinciding with that of PT. At the trough stationary point of PT or SS, body center of gravity (COG) trajectory exhibits a strong correlation with PT or SS kinematics and synchronous transitions in displacement velocity and direction, highlighting the crucial role of pelvic posture adjustment in body COG regulation.

Conclusions

A biomechanical framework for investigating the kinematic characteristics of pelvic angles during the STS task is proposed. In healthy individuals, the kinematic patterns of pelvic motion during STS demonstrate prominent nonlinear characteristics, accompanied by distinct stationary points in the pelvic characteristic angles around the mid‐STS phase. The current acetabular safe zone is insufficient to account for dynamic variations in pelvic orientation, and the identified critical stationary points of pelvic angles during the mid‐STS phase may provide theoretical support for preoperative planning and postoperative rehabilitation in patients undergoing THA.

Subjects

MeSH terms (MEDLINE)

PelvisPelvic BonesStanding PositionSitting PositionHumansBiomechanical PhenomenaAdultMaleFemaleArthroplasty, Replacement, HipMotion Capture

Author keywords

kinematicspelvispostural transitionstotal hip arthroplasty

Authors and institutions

  • Department of Engineering Mechanics, Applied Mechanics Lab, School of Aerospace, Tsinghua University, Beijing, China.
  • Department of Mechanics, Beijing University of Technology, Beijing, China.
  • Department of Orthopaedics, Peking University Third Hospital, Beijing, China.
  • Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China.

ORCID profiles: Hua Tian

Funding

  • National Natural Science Foundation of China

Cite

APA

Zheng, H., Liu, C. X., Xin, H., Tian, H., Liu, Z., & Zhao, M. (2026). Temporal Evolution and Stationary Point Mechanisms of Pelvic Characteristic Angles Throughout the Sit‐to‐Stand Cycle. Orthopaedic Surgery, 18(8), 1688-1699. https://doi.org/10.1111/os.70366

Vancouver

Zheng H, Liu CX, Xin H, Tian H, Liu Z, Zhao M. Temporal Evolution and Stationary Point Mechanisms of Pelvic Characteristic Angles Throughout the Sit‐to‐Stand Cycle. Orthopaedic Surgery. 2026;18(8):1688-1699. doi:10.1111/os.70366

BibTeX
@article{Zheng2026,
  author = {Zheng, Houwen and Liu, Chen-Xu and Xin, Haoyue and Tian, Hua and Liu, Zhanli and Zhao, Minwei},
  title = {Temporal Evolution and Stationary Point Mechanisms of Pelvic Characteristic Angles Throughout the Sit‐to‐Stand Cycle},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {8},
  pages = {1688--1699},
  doi = {10.1111/os.70366}
}
Start for free →