Normal Range and Influencing Factors of Distal Radioulnar Joint Translation: A Descriptive Study
Orthopaedic Surgery · 2026-05 · 18 (5) · 1020-1028
DOI: 10.1111/os.70322 ↗At a glance
Journal article in Orthopaedic Surgery, published online on 2026-04-19. Written by Shijie Jia and 5 co-authors. Institution: Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China. Major MEDLINE topics: Wrist Joint, Range of Motion, Articular, Joint Instability, Radius. 18 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Beijing Hospitals Authority's Ascent Plan, Beijing Municipal Health Commission, Beijing Natural Science Foundation-Joint Funds of Haidian Original Innovation Project.
Abstract (original language)
Objective
Distal radioulnar joint (DRUJ) instability is commonly assessed clinically via physical examination, such as a ballottement test, which evaluates palmar‐dorsal translation of the radius relative to the ulna. However, the normal physiological range of translation and the factors influencing it remain poorly defined, limiting the test's diagnostic precision. This study aimed to quantify the normal range of DRUJ translation and identify its associated factors in a healthy population.
Methods
Healthy adult participants were recruited between January 1, 2025, and April 30, 2025. Data on occupation, gender, age, height, weight, handedness, wrist circumference, forearm length, and grip strength were recorded. A custom‐designed device was used to measure the palmar, dorsal, and combined DRUJ translations in forearm pronation, supination, and neutral positions. Univariate and multivariate analyses were performed to identify factors influencing translation.
Results
The mean (±SD) combined DRUJ translation was 11.9 ± 4.2 mm in pronation, 12.4 ± 3.9 mm in supination, and 13.3 ± 4.6 mm in the neutral position. Significant side‐to‐side differences were observed for all translations in pronation and for both palmar and dorsal translations in the neutral position. No significant side‐to‐side difference was found in supination. Compared to pronation and supination, combined and palmar translations were significantly greater in the neutral position. Conversely, dorsal translation was greatest in supination. Multivariate analysis revealed that combined DRUJ translation in supination was significantly influenced by grip strength, forearm length, weight, and age.
Conclusion
Our findings establish reference values for DRUJ translation and demonstrate that it is influenced by forearm position and multiple factors. To improve the clinical utility of the ballottement test, we recommend performing it in forearm supination while comparing both limbs. Specifically, combined DRUJ translation with forearm supinated is significantly affected by grip strength, forearm length, weight, and age. Level of Evidence 3.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
- Beijing Research Institute of Traumatology and Orthopaedics, Beijing, China.
ORCID profiles: Zhe Yi
Funding
- Beijing Hospitals Authority's Ascent Plan
- Beijing Municipal Health Commission
- Beijing Natural Science Foundation-Joint Funds of Haidian Original Innovation Project
Cite
APA
Jia, S., Xiang, Z., Yi, Z., Chen, S., Liu, B., & Yin, Y. (2026). Normal Range and Influencing Factors of Distal Radioulnar Joint Translation: A Descriptive Study. Orthopaedic Surgery, 18(5), 1020-1028. https://doi.org/10.1111/os.70322
Vancouver
Jia S, Xiang Z, Yi Z, Chen S, Liu B, Yin Y. Normal Range and Influencing Factors of Distal Radioulnar Joint Translation: A Descriptive Study. Orthopaedic Surgery. 2026;18(5):1020-1028. doi:10.1111/os.70322
BibTeX
@article{Jia2026,
author = {Jia, Shijie and Xiang, Ziyue and Yi, Zhe and Chen, Shanlin and Liu, Bo and Yin, Yaobin},
title = {Normal Range and Influencing Factors of Distal Radioulnar Joint Translation: A Descriptive Study},
journal = {Orthopaedic Surgery},
year = {2026},
volume = {18},
number = {5},
pages = {1020--1028},
doi = {10.1111/os.70322}
}
EUVIMED