H‐Shaped Anatomical Titanium Plate: Biomechanical Validation and Clinical Application in the Treatment of Complex Posterior Wall/Column Acetabular Fractures
Orthopaedic Surgery · 2025
DOI: 10.1111/os.70053 ↗At a glance
Validierungsstudie in Orthopaedic Surgery, 2025. Written by Qiaoli Zhang and 10 co-authors. Institution: Department of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China. Major MEDLINE topics: Bone Plates, Acetabulum, Fracture Fixation, Internal, Fractures, Bone. Cited 2 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Nanping City Joint Fund Project for Scientific and Technological Innovation in the Medical and Health Field, China, Fujian Provincial Natural Science Foundation of China.
Abstract (original language)
Objective
Approximately 80% of acetabular fractures involve the posterior wall and posterior column, which are complex and challenging to treat. The H‐shaped anatomical titanium plate ( HTP ) facilitates anatomical reduction, minimizes complications, and enhances safety, efficacy, and speed. This study aims to conduct biomechanical testing and clinical evaluation of HTP to assess its stability and efficacy in treating these fractures.
Methods
In the biomechanical research, posterior column with posterior wall fractures was created on nine acetabular models procured from Sawbones, USA and were allocated to three fixation groups: (1) a single reconstruction plate combined with a single cortical screw ( PCS ), (2) double parallel reconstruction plates ( 2P ), (3) HTP . Following anatomic reduction, cyclic loading and destructive experiments were conducted to assess the efficacy of different fixation devices under various loads for the posterior wall and column, as well as their peak load and structural stiffness. Additionally, we retrospectively analyzed the clinical data of 53 patients (46 males, 7 females; mean follow‐up 24.6 ± 3.2 months) with the HTP at our hospital from April 2017 to January 2023. Clinical outcomes mainly included changes in postoperative pain, reduction quality (Matta criteria), hip function (Merle d'Aubigné Postel/Harris scores), and the incidence of complications.
Results
Biomechanical results showed that in cyclic loading tests, the relative displacement of the posterior wall and the posterior column fixed with the HTP was smallest, with statistically significant differences ( p < 0.05). In the destructive experiment, compared to the 2P group (2062.89 ± 375.45 N, 412.16 ± 25.87 N/mm) and the PCS group (1477.89 ± 161.57 N, 204.21 ± 34.94 N/mm), the HTP group (3342.67 ± 354.15 N, 652.52 ± 24.25 N/mm) demonstrated superior peak load and structural stiffness, with statistically significant differences ( p < 0.05). Clinically, Postoperative Visual Analogue Scale scores significantly decreased, indicating effective pain management. 84.91% achieved anatomic reduction, with 92.45% and 90.56% good/excellent functional outcomes (Merle d'Aubigné Postel and Harris scores, respectively). The incidence of various complications was low, with no cases of implant failure observed.
Conclusions
The HTP demonstrates robust stability in biomechanical experiments, offering distinct advantages for clinical applications and widespread adoption. In the treatment of the posterior column/posterior wall fractures, the integrated fixation of HTP aligns with the physiological anatomy of the acetabulum and has the advantages of simple operation, short operation time, strong stability, minimal risk of vascular and nerve injury, and fewer complications.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.
- Department of Clinical Medicine, Fujian Medical University, Fuzhou, China.
ORCID profiles: Qiaoli Zhang, Liang Jin, Xiaorui Hao, Weijie Zheng, Fei Zhou, Shuxin Zhang, Tianfeng Li, Xiaohui Xiong, Yihan He, Jiexin Huang
Funding
- Nanping City Joint Fund Project for Scientific and Technological Innovation in the Medical and Health Field, China
- Fujian Provincial Natural Science Foundation of China
Cite
APA
Zhang, Q., Jin, L., Hao, X., Zheng, W., Zhou, F., Zhang, S., Li, T., Xiong, X., He, Y., Chen, X., & Huang, J. (2025). H‐Shaped Anatomical Titanium Plate: Biomechanical Validation and Clinical Application in the Treatment of Complex Posterior Wall/Column Acetabular Fractures. Orthopaedic Surgery. https://doi.org/10.1111/os.70053
Vancouver
Zhang Q, Jin L, Hao X, Zheng W, Zhou F, Zhang S, et al. H‐Shaped Anatomical Titanium Plate: Biomechanical Validation and Clinical Application in the Treatment of Complex Posterior Wall/Column Acetabular Fractures. Orthopaedic Surgery. 2025. doi:10.1111/os.70053
BibTeX
@article{Zhang2025,
author = {Zhang, Qiaoli and Jin, Liang and Hao, Xiaorui and Zheng, Weijie and Zhou, Fei and Zhang, Shuxin and Li, Tianfeng and Xiong, Xiaohui and He, Yihan and Chen, Xiaojie and Huang, Jiexin},
title = {H‐Shaped Anatomical Titanium Plate: Biomechanical Validation and Clinical Application in the Treatment of Complex Posterior Wall/Column Acetabular Fractures},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.70053}
}
EUVIMED