EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Feasibility and Mechanical Strength Evaluation of New Customized Implants for Tibial Plateau Fractures Fixation

Meng Li, Mengmeng Hu, Xiaomeng Ren, Yi Gao, Longbo Du, Yu Jiang, Wei Zhang iD

Orthopaedic Surgery · 2025-06 · 17 (6) · 1791-1803

DOI: 10.1111/os.70041 ↗

At a glance

Journal article in Orthopaedic Surgery, published online on 2025-04-20. Written by Meng Li and 6 co-authors. Institution: Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China. Major MEDLINE topics: Tibial Fractures, Fracture Fixation, Internal, Bone Plates, Prosthesis Design. Cited 3 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Development and Clinical Demonstration of an Innovative Internal Fixation System for Femoral Neck Fractures.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background and Objective Customized implants could improve the capture of fracture fragments for strengthened stability of tibial plateau fractures (TPFs) fixation. This study aimed to validate the feasibility of customized implants through optimized manufacturing within a clinically acceptable timeframe and evaluate the mechanical strength of customized internal implants through finite element analysis.

Methods

A retrospective was conducted. From May 1, 2023, to June 1, 2023, 10 patients with TPFs were treated at our hospital using various new internal fixation systems combined with customized technology. The indicators of patients characteristics, operation, and follow‐up were collected, such as the cause of trauma, fresh or old, fracture classification, blood loss, Lysholm score, EQ‐5D‐3L score, and so on. Additionally, we created a Schatzker IV TPF model with two separated fragments in the medial to compare the biomechanical strength and directional deformation between standard medial dual plates (MDPs) and medial customized plate (MCP).

Results

The study found that the entire process of implant fabrication can be completed within a clinically acceptable timeframe of 3–4 days. We designed specific types of plates for different types of fractures, such as semi‐circumferential plates for lateral TPFs, γ‐type plates for medial TPFs, and pistol‐type and wing‐type plates for posterior TPFs. Follow‐up analysis showed operative times of 1.37 ± 0.58 h, intraoperative blood loss of 260 ± 179.20 mL, and favorable functional outcomes: Lysholm score 88.6 ± 4.93, knee ROM 103.5° ± 11.56°, and EQ‐5D‐3L score 0.87 ± 0.47. Additionally, the γ‐type plate showed comparable strength to the MDPs system via finite element analysis and demonstrated a more vital ability to resist the separation of fracture fragments, with the maximum displacement of MDPs (0.61878 mm) 2.4 times higher than that of MCP (0.26124 mm).

Conclusions

Using customized internal fixation systems provided solutions to challenges of complex fractures, within a clinically acceptable timeframe of 3–4 days. Notably, the study showed that the strength of customized internal fixation systems of γ‐shaped plate was comparable to that of conventional implants. This innovative approach offered a new avenue for managing TPFs and even complex limb fractures.

Subjects

MeSH terms (MEDLINE)

Tibial FracturesFracture Fixation, InternalBone PlatesProsthesis DesignHumansRetrospective StudiesFeasibility StudiesMaleMiddle AgedFemaleAdultFinite Element AnalysisAgedBiomechanical PhenomenaTibial Plateau Fractures

Author keywords

additive and subtractive manufacturingcustomized implantfinite element analysistibial plateau fracture

Authors and institutions

  • Senior Department of Orthopedics, the Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Chinese PLA General Hospital, Beijing, China.

ORCID profiles: Wei Zhang

Funding

  • Development and Clinical Demonstration of an Innovative Internal Fixation System for Femoral Neck Fractures

Cite

APA

Li, M., Hu, M., Ren, X., Gao, Y., Du, L., Jiang, Y., & Zhang, W. (2025). Feasibility and Mechanical Strength Evaluation of New Customized Implants for Tibial Plateau Fractures Fixation. Orthopaedic Surgery, 17(6), 1791-1803. https://doi.org/10.1111/os.70041

Vancouver

Li M, Hu M, Ren X, Gao Y, Du L, Jiang Y, et al. Feasibility and Mechanical Strength Evaluation of New Customized Implants for Tibial Plateau Fractures Fixation. Orthopaedic Surgery. 2025;17(6):1791-1803. doi:10.1111/os.70041

BibTeX
@article{Li2025,
  author = {Li, Meng and Hu, Mengmeng and Ren, Xiaomeng and Gao, Yi and Du, Longbo and Jiang, Yu and Zhang, Wei},
  title = {Feasibility and Mechanical Strength Evaluation of New Customized Implants for Tibial Plateau Fractures Fixation},
  journal = {Orthopaedic Surgery},
  year = {2025},
  volume = {17},
  number = {6},
  pages = {1791--1803},
  doi = {10.1111/os.70041}
}
Start for free →