Creating Perforations in the Sclerotic Region of the Proximal Tibia During Total Knee Arthroplasty to Enhance Prosthesis Stability
Orthopaedic Surgery · 2025
DOI: 10.1111/os.70025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Surgery, 2025. Verfasst von Chao Sun und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Orthopaedic Center, The First Hospital of Jilin University, Jilin University, Changchun, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tibia, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
In patients with varus deformity of the knee, the redistribution of the subchondral bone mineral density (BMD) of the tibia leads to sclerotic zones that may cause osteoarthritis. Drilling the sclerotic area of the tibia prior to cementing during total knee arthroplasty is advisable practice. However, the extent of the sclerotic area and the effect of drilling on the tibial component are not well defined. We aimed to quantify the BMD and sclerotic bone distribution of the knee to clarify the effect of drilling on the stability of the prosthesis.
Methods
Our retrospective cohort study enrolled a total of 97 patients from December 2018 to December 2019, categorized into drilled and nondrilled groups, with their computed tomography (CT) knee joint images documented. The proximal tibia image was divided into nine regions, the BMD of each region calculated, and CT values compared between the affected and normal sides. We established finite element models to analyze the drilling and stress distribution. The differences in CT values were assessed using the paired t test and Wilcoxon signed‐rank test.
Results
The mean thickness of sclerotic bone was 7.7 ± 1.4 mm, and the surface area was 441.9 ± 89.4 mm 2 . The CT values of the affected anteromedial, anterolateral, mediomedial, mediolateral, posteromedial, posteromedian, and posterolateral tibial areas were significantly higher than their normal counterparts. Stress concentration around the boreholes in all finite element models is minimal, with stress values ranging from 0.01 to 3.73 MPa, markedly lower than the 13.93 MPa observed in the undrilled model.
Conclusion
Abnormal stress in the proximal tibia alters the distribution pattern of BMD, and drilling in the sclerotic area is associated with improved prosthesis stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Orthopaedic Center, The First Hospital of Jilin University, Jilin University, Changchun, China.
- Department of Neurology, Neuroscience Center, The First Hospital of Jilin University, Jilin University, Changchun, China.
- Department of Orthopaedics, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
ORCID-Profile: Chao Sun, Shuqiang Li
Zitieren
APA
Sun, C., Wang, C., Li, J., Liu, C., Wei, Z., Bi, Z., Li, Y., & Li, S. (2025). Creating Perforations in the Sclerotic Region of the Proximal Tibia During Total Knee Arthroplasty to Enhance Prosthesis Stability. Orthopaedic Surgery. https://doi.org/10.1111/os.70025
Vancouver
Sun C, Wang C, Li J, Liu C, Wei Z, Bi Z, et al. Creating Perforations in the Sclerotic Region of the Proximal Tibia During Total Knee Arthroplasty to Enhance Prosthesis Stability. Orthopaedic Surgery. 2025. doi:10.1111/os.70025
BibTeX
@article{Sun2025,
author = {Sun, Chao and Wang, Chunyan and Li, Jintang and Liu, Chengyan and Wei, Zhilin and Bi, Zhiguo and Li, Yeran and Li, Shuqiang},
title = {Creating Perforations in the Sclerotic Region of the Proximal Tibia During Total Knee Arthroplasty to Enhance Prosthesis Stability},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.70025}
}
EUVIMED