What Is the Optimal Position of Low Tibial Tunnel in Transtibial Posterior Cruciate Ligament Reconstruction? A Quantitative Analysis Based on 2D CT Images and 3D Knee Models
Orthopaedic Surgery · 2025
DOI: 10.1111/os.14379 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Surgery, 2025. Verfasst von Laiwei Guo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Tibia, Imaging, Three-Dimensional, Posterior Cruciate Ligament Reconstruction. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cuiying Scientific and Technological Innovation Program of Lanzhou University Second Hospital, Natural Science Foundation of Gansu Province, Cuiying Scientific Training Program for Undergraduates of The Second Hospital & Clinical Medical School, Lanzhou University.
Abstract (Originalsprache)
Objectives
There is currently no consensus on the optimal placement of the low tibial tunnel for posterior cruciate ligament (PCL) reconstruction. This study aimed to perform the quantitative measurements of the optimal tangential low tibial‐tunnel (OTLT) parameters based on 2D CT images and 3D virtual knee models and expect to provide reference data for clinical creation of the OTLT during the arthroscopic transtibial PCL reconstruction.
Methods
This was a retrospective CT image study. A total of 101 patients between January 2018 and December 2020 were included in our study for analysis. The CT image data of included patients were imported into Mimics software to create the 3D knee models, and the OTLT for PCL reconstruction was simulated on 2D CT images and 3D knee models, respectively. With that, the distances of the tunnel's entry (ADT) and exit points (BDT) to the tibial plateau, the length of the tunnel (LT), and the angle of the tunnel (AT) were measured. Variables were compared using the independent t ‐test or the Mann–Whitney u test. Correlation analyses between the data and patient demographic factors were performed using the Pearson or Spearman correlation analysis. One‐way ANOVA was used to compare differences among height subgroups.
Results
The mean ADT, LT, and AT on 2D CT images were 57.96 ± 5.34 mm, 39.92 ± 5.49 mm, and 37.23° ± 4.57° respectively, smaller than the values on 3D knee models (61.86 ± 6.80 mm, 45.56 ± 4.27 mm, and 48.17° ± 6.12°, all p values < 0.001). While the mean BDT on 2D CT images was significantly larger than 3D knee models (35.28 ± 3.07 mm vs. 29.72 ± 3.00 mm, p < 0.001). The BDT showed larger in males than females, the LT showed larger in the taller group, and the AT seemed to be larger in females and shorter people (all p values < 0.05).
Conclusion
The quantitative parameters of the OTLT based on 2D CT images and 3D knee models can be used as reference data for clinical surgeons to build an anteromedial OTLT during the arthroscopic transtibial PCL reconstruction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu, China.
- Orthopaedics Clinical Medical Research Center of Gansu Province, Lanzhou University Second Hospital, Lanzhou, Gansu, China.
- Intelligent Orthopaedic Industry Technology Center of Gansu Province, Lanzhou University Second Hospital, Lanzhou, Gansu, China.
- Department of Pediatrics, Lanzhou University Second Hospital, Lanzhou, Gansu, China.
- Department of Anesthesiology and Operation, Lanzhou University Second Hospital, Lanzhou, Gansu, China.
- Academy for Engineering and Technology, Fudan University, Shanghai, China.
ORCID-Profile: Yayi Xia
Förderung
- Cuiying Scientific and Technological Innovation Program of Lanzhou University Second Hospital
- Natural Science Foundation of Gansu Province
- Cuiying Scientific Training Program for Undergraduates of The Second Hospital & Clinical Medical School, Lanzhou University
- Innovation Fund Project of Colleges and Universities in Gansu Province
- Medical Innovation and Development Project of Lanzhou University
- National Natural Science Foundation of China
Zitieren
APA
Guo, L., Sheng, X., Dai, C., Wang, X., Zhao, L., Zhang, X., Geng, B., Liu, Z., Bai, R., Zheng, X., Wu, M., Teng, Y., & Xia, Y. (2025). What Is the Optimal Position of Low Tibial Tunnel in Transtibial Posterior Cruciate Ligament Reconstruction? A Quantitative Analysis Based on 2D CT Images and 3D Knee Models. Orthopaedic Surgery. https://doi.org/10.1111/os.14379
Vancouver
Guo L, Sheng X, Dai C, Wang X, Zhao L, Zhang X, et al. What Is the Optimal Position of Low Tibial Tunnel in Transtibial Posterior Cruciate Ligament Reconstruction? A Quantitative Analysis Based on 2D CT Images and 3D Knee Models. Orthopaedic Surgery. 2025. doi:10.1111/os.14379
BibTeX
@article{Guo2025,
author = {Guo, Laiwei and Sheng, Xiaoyun and Dai, Caijuan and Wang, Xingwen and Zhao, Lianggong and Zhang, Xiaohui and Geng, Bin and Liu, Zhongcheng and Bai, Rui and Zheng, Xiaoli and Wu, Meng and Teng, Yuanjun and Xia, Yayi},
title = {What Is the Optimal Position of Low Tibial Tunnel in Transtibial Posterior Cruciate Ligament Reconstruction? A Quantitative Analysis Based on 2D CT Images and 3D Knee Models},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.14379}
}
EUVIMED