Freehand Placement of a Transiliac‐Transsacral Screw for Fixation of Posterior Pelvic Ring Injuries
Orthopaedic Surgery · 2025
DOI: 10.1111/os.14326 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Surgery, 2025. Verfasst von Guangping Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, The Fourth Medical Center, Chinese PLA General Hospital, Beijing, China. Hauptthemen laut MEDLINE: Bone Screws, Pelvic Bones, Fracture Fixation, Internal, Fractures, Bone. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
There are many advantages to stabilize the posterior pelvic ring injuries with a transiliac‐transsacral (TITS) screw percutaneously. To identify the correct entry point and insert a guidewire accurately for a TITS screw, we propose a method of specifying the optimal entry point, and introduce a technique of enabling freehand placement of a guidewire with fluoroscopic guidance.
Methods
In this retrospective study, 116 patients who underwent pelvic CT scans and pelvic lateral radiographs at our institution from January 2020 to April 2022 were enrolled. The optimal entry point for a TITS screw was formulated in the strict mid‐sagittal CT plane, and then transferred to the pelvic lateral radiograph relying on the sacral cortexes which were easily visible even in the poor fluoroscopy. The relative position of this point to other anatomical markers was checked to confirm its feasibility as an entry point. With the method to locate the entry point, 18 patients suffered the posterior pelvic ring injuries were treated with TITS screws through hammering a reverse Kirschner wire (K‐wire) to insert a guidewire assisted by a canula, followed by the validation of the screw placement accuracy.
Results
The transferred point in radiograph was consistently beneath the sacral alar slope, and located posteroinferior to the iliac cortical density (ICD) and anterosuperior to the sacral nerve root tunnel in all 116 patients. In clinical practice, 18 TITS screws were successfully placed in 18 patients without cortex violation. The average operative time for each screw was 20.11 ± 6.29 min, with an average of 14.11 ± 6.81 fluoroscopic shots per screw. At the 3‐month follow‐up, fracture healing was confirmed in all patients. The average Majeed score was 89.61 ± 6.90 at the final follow‐up.
Conclusions
It's feasible to identify an entry point for a TITS screw based on the sacral cortexes, and hammering a reverse K‐wire assisted by a percutaneous kyphoplasty (PKP) canula is a safe and practical technique for guidewire insertion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, The Fourth Medical Center, Chinese PLA General Hospital, Beijing, China.
- Department of Orthopaedics, Zibo Central Hospital, Zibo, China.
ORCID-Profile: Guangping Liu, Jiaqi Li, Hua Chen
Zitieren
APA
Liu, G., Chen, Z., Cao, W., Zheng, Y., Li, J., He, J., Li, C., Chen, H., & Tang, P. (2025). Freehand Placement of a Transiliac‐Transsacral Screw for Fixation of Posterior Pelvic Ring Injuries. Orthopaedic Surgery. https://doi.org/10.1111/os.14326
Vancouver
Liu G, Chen Z, Cao W, Zheng Y, Li J, He J, et al. Freehand Placement of a Transiliac‐Transsacral Screw for Fixation of Posterior Pelvic Ring Injuries. Orthopaedic Surgery. 2025. doi:10.1111/os.14326
BibTeX
@article{Liu2025,
author = {Liu, Guangping and Chen, Zhiguang and Cao, Wenhao and Zheng, Yubo and Li, Jiaqi and He, Jie and Li, Changda and Chen, Hua and Tang, Peifu},
title = {Freehand Placement of a Transiliac‐Transsacral Screw for Fixation of Posterior Pelvic Ring Injuries},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.14326}
}
EUVIMED