The Influence of Zero‐Profile Implant Selection on the Outcomes of Anterior Cervical Discectomy and Fusion
Orthopaedic Surgery · 2025
DOI: 10.1111/os.14322 ↗At a glance
Journal article in Orthopaedic Surgery, 2025. Written by Xing-Jin Wang and 6 co-authors. Institution: Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan, China. Major MEDLINE topics: Spinal Fusion, Cervical Vertebrae, Diskectomy, Intervertebral Disc Degeneration. Cited 4 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: 1.3.5 project for Postdoctoral Foundation of West China Hospital of Sichuan University, National Natural Science Foundation of China, the Foundation of Science and Technology Department of Sichuan Province.
Abstract (original language)
Objectives
Anterior cervical discectomy and fusion (ACDF) has been widely used in the treatment of cervical degenerative disc disease (CDDD). Previous studies have demonstrated that the size of implants in ACDF determines radiological and clinical outcomes. However, the principles of choosing an appropriate implant size in ACDF remain controversial. The study aimed to elucidate the influence of the cage size of Zero‐profile implant system and offer proposals on the selection of implant size during ACDF.
Methods
This retrospective study analyzed 109 patients who underwent single‐level ACDF from March 2011 to April 2020 with the Zero‐profile implant system. The patients were categorized into two groups based on the preoperative mean height of adjacent segments (Hm). Clinical outcomes included the Japanese Orthopaedic Association scores (JOA), Neck Disability Index (NDI) and visual analog scale (VAS). In addition, radiographical analysis encompassed cervical lordosis (CL), functional spinal unit (FSU) angle, range of motion (ROM) of the total cervical spine and the FSU, anterior and posterior FSU height, C1–C7 sagittal vertical axis (SVA), C2–C7 SVA, the center of gravity of the head (CGH)‐C7 SVA as well as T1 slope (T1S) measurements. Besides, bone fusion rates, anterior bone loss, subsidence, and adjacent segment degeneration were also recorded.
Results
Overall, 37 patients in Group A had an implant size ≥ Hm while 72 patients in Group B had an implant size < Hm. The preoperative general data and radiological parameters were comparable between the groups. At the last follow‐up, both groups had satisfactory clinical outcomes. As for radiological outcomes, the anterior and posterior FSU heights were significantly higher in Group A compared to Group B ( p < 0.05) after ACDF. Besides, both groups corrected and maintained the CL and FSU. However, the average C1–C7 SVA and C2–C7 SVA at the last follow‐up were significantly higher in the Group B than in the Group A (C1–C7 SVA: 27.42 ± 9.23 mm vs. 31.76 ± 10.68 mm, p = 0.038; C2–C7 SVA: 14.65 ± 7.27 mm vs. 19.64 ± 8.68, p = 0.003). Additionally, the fusion rates were significantly higher in Group A at the first two follow‐up visits.
Conclusion
Our study showed that an appropriate size of Zero‐profile implant system is crucial to achieving favorable clinical and radiological outcomes after performing ACDF. Implants with a larger height but not oversize could maintain the cervical sagittal balance and FSU height and achieve early bone fusion. Therefore, a larger height might be a better choice for achieving a satisfactory long‐term prognosis if Zero‐profile implants of adjacent size both fit the disc space properly.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
- Medical Faculty, Heidelberg University, Heidelberg, Germany.
ORCID profiles: Xing-Jin Wang, Bei-Yu Wang
Funding
- 1.3.5 project for Postdoctoral Foundation of West China Hospital of Sichuan University
- National Natural Science Foundation of China
- the Foundation of Science and Technology Department of Sichuan Province
Cite
APA
Wang, X. J., He, J. B., Wu, T. K., Wang, B. Y., Rong, X., Gong, Q., & Liu, H. (2025). The Influence of Zero‐Profile Implant Selection on the Outcomes of Anterior Cervical Discectomy and Fusion. Orthopaedic Surgery. https://doi.org/10.1111/os.14322
Vancouver
Wang XJ, He JB, Wu TK, Wang BY, Rong X, Gong Q, et al. The Influence of Zero‐Profile Implant Selection on the Outcomes of Anterior Cervical Discectomy and Fusion. Orthopaedic Surgery. 2025. doi:10.1111/os.14322
BibTeX
@article{Wang2025,
author = {Wang, Xing-Jin and He, Jun-Bo and Wu, Ting-Kui and Wang, Bei-Yu and Rong, Xin and Gong, Quan and Liu, Hao},
title = {The Influence of Zero‐Profile Implant Selection on the Outcomes of Anterior Cervical Discectomy and Fusion},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.14322}
}
EUVIMED