The Efficacy of Modified Ilizarov Distraction ‐Tension Device on Limb Wound Difficult to Cover with Skin Flaps
Orthopaedic Surgery · 2024
DOI: 10.1111/os.14217 ↗At a glance
Journal article in Orthopaedic Surgery, 2024. Written by Yueliang Zhu and 4 co-authors. Institution: The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China. Major MEDLINE topics: Ilizarov Technique, Surgical Flaps, Wound Healing. Cited 4 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: The Twelfth Batch of Youth Doctoral Research Rotation Funding for the Second Affiliated Hospital of Zhejiang University School of Medicine.
Abstract (original language)
Introduction
Closure of complex limb wounds poses challenges and requires innovative approaches. This research aimed to evaluate the effectiveness of a modified distraction‐tension device using Ilizarov external fixation for wound closure in challenging cases.
Methods
A retrospective analysis was conducted on 43 patients with extremity wounds that were difficult to cover with skin flaps between January 2019 and December 2022. Tension‐relieving traction was applied using the Ilizarovexternal fixator apparatus, tailored to individual wound characteristics. Three types of wire–pin connections were used in this study. The distraction begins on the third postoperative day, with a speed of 0.5mm/d. Clinical wound healing scores were evaluated at 5 and 30 days postoperatively. Complications were documented following the Paley classification system.
Results
Traction using modified Ilizarovexternal fixation promoted a significant reduction in wound size. The mean traction period was 11.2 ± 7.3 days, and the mean healing duration was 17.0 ± 3.7 days. The clinical wound healing score improved from 3.7 ± 2.9 at 5 days to 1.7 ± 0.7 at 30 days postoperatively ( p < 0.05). Complications were minimal, with no significant obstacles or sequelae observed. Direct closure healing was achieved in 21 cases, skin graft healing in 13 cases, and suture healing in 9 cases. No recurrences were reported. Using Paley's classified complications, there were 17 problems, 9 obstacles, and 0 sequelae.
Conclusion
The Ilizarov tension‐relieving traction shows promise in facilitating wound closure that is challenging to manage with skin flaps. The modified three types of pin–skin connection configuration could satisfy various types of wound closure.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
- 920th Hospital of Joint Logistics Support Force of PLA, Kunming, China.
ORCID profiles: Zhen Shi
Funding
- The Twelfth Batch of Youth Doctoral Research Rotation Funding for the Second Affiliated Hospital of Zhejiang University School of Medicine
Cite
APA
Zhu, Y., Pan, S., Xu, Y., Shi, J., & Shi, Z. (2024). The Efficacy of Modified Ilizarov Distraction ‐Tension Device on Limb Wound Difficult to Cover with Skin Flaps. Orthopaedic Surgery. https://doi.org/10.1111/os.14217
Vancouver
Zhu Y, Pan S, Xu Y, Shi J, Shi Z. The Efficacy of Modified Ilizarov Distraction ‐Tension Device on Limb Wound Difficult to Cover with Skin Flaps. Orthopaedic Surgery. 2024. doi:10.1111/os.14217
BibTeX
@article{Zhu2024,
author = {Zhu, Yueliang and Pan, Sunwen and Xu, Yongqing and Shi, Jian and Shi, Zhen},
title = {The Efficacy of Modified Ilizarov Distraction ‐Tension Device on Limb Wound Difficult to Cover with Skin Flaps},
journal = {Orthopaedic Surgery},
year = {2024},
doi = {10.1111/os.14217}
}
EUVIMED