EUVIMEDOpdag EUVIMED
Multizentrische StudieRandomisierte kontrollierte StudieVergleichsstudieOpen access · CC BY-NC 4.0

Early Radiographic and Clinical Outcomes of Robotic‐arm‐assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial

Xiao Geng, Yuhang Zheng iD, Yang Li, Minwei Zhao, Yanqing Liu, Zijian Li, Hong Cai, Ming Zhang, Xinfeng Yan, Zhiwen Sun, Xin Lv, Feng Guo and 2 more

Orthopaedic Surgery · 2024-11 · 16 (11) · 2732-2740

DOI: 10.1111/os.14196 ↗

At a glance

Multizentrische Studie in Orthopaedic Surgery, published online on 2024-08-12. Written by Xiao Geng and 13 co-authors. Institution: Peking University Third Hospital, Department of Orthopaedics/Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education/…. Major MEDLINE topics: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures. Cited 20 times so far (Crossref); 43 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Beijing Municipal Natural Science Foundation, Natural Science Foundation of Beijing Municipality.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

A robotic system was recently introduced to improve prosthetic alignment during total knee arthroplasty (TKA). The purpose of this multicenter, prospective, randomized controlled trial (RCT) was to determine whether robotic‐arm‐assisted TKA improves clinical and radiological outcomes when compared to conventional TKA.

Methods

One hundred and thirty patients who underwent primary TKA were enrolled in this prospective, randomized controlled trial, which was conducted at three hospitals. Five patients were lost to follow‐up 6 weeks after surgery. Therefore, 125 participants (63 in the intervention group and 62 in the control group) remained in the final analysis. The primary outcome was the rate at which the mechanical axis of the femur deviated by less than 3° from the mechanical axis of the tibia. This was evaluated by full‐length weight‐bearing X‐rays of the lower limb 6 weeks postoperatively. Secondary outcomes included operation times, 6‐week postoperative functional outcomes evaluated by the American Knee Society score (KSS) and the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), short form‐36 (SF‐36) health survey results, and the occurrence of adverse events (AEs) and serious adverse events (SAEs).

Results

At 6 weeks postoperatively, we found that the rate of radiographic inliers was significantly higher in the intervention group (78.7% vs 51.6%; p = 0.00; 95% confidence interval, 10.9% to 43.2%). The operation was significantly longer in the intervention group than in the control group (119.5 vs 85.0 min; p = 0.00). There were no significant differences in the 6‐week postoperative functional outcomes, SF‐36, AEs, and SAEs between the two groups. There were no AEs or SAEs that were determined to be “positively related” to the robotic system.

Conclusion

Robotic‐arm‐assisted TKA is safe and effective, as demonstrated in this trial.

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresHumansMaleFemaleAgedMiddle AgedProspective StudiesRadiographyOsteoarthritis, Knee

Author keywords

Clinical outcomeRadiological outcomeRobotic‐arm‐assistedTotal knee arthroplasty

Authors and institutions

  • Peking University Third Hospital, Department of Orthopaedics/Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education/Beijing Key Laboratory of Spinal Disease Research, Beijing, China.
  • The First Affiliated Hospital of Shandong First Medical University/Shandong Provincial Qianfoshan Hospital, Jinan, China.
  • Chifeng Municipal Hospital, Chifeng, Inner Mongolia, China.

ORCID profiles: Yuhang Zheng, Hua Tian

Funding

  • Beijing Municipal Natural Science Foundation
  • Natural Science Foundation of Beijing Municipality

Cite

APA

Geng, X., Zheng, Y., Li, Y., Zhao, M., Liu, Y., Li, Z., Cai, H., Zhang, M., Yan, X., Sun, Z., Lv, X., Guo, F., Li, F., & Tian, H. (2024). Early Radiographic and Clinical Outcomes of Robotic‐arm‐assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial. Orthopaedic Surgery, 16(11), 2732-2740. https://doi.org/10.1111/os.14196

Vancouver

Geng X, Zheng Y, Li Y, Zhao M, Liu Y, Li Z, et al. Early Radiographic and Clinical Outcomes of Robotic‐arm‐assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial. Orthopaedic Surgery. 2024;16(11):2732-2740. doi:10.1111/os.14196

BibTeX
@article{Geng2024,
  author = {Geng, Xiao and Zheng, Yuhang and Li, Yang and Zhao, Minwei and Liu, Yanqing and Li, Zijian and Cai, Hong and Zhang, Ming and Yan, Xinfeng and Sun, Zhiwen and Lv, Xin and Guo, Feng and Li, Feng and Tian, Hua},
  title = {Early Radiographic and Clinical Outcomes of Robotic‐arm‐assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial},
  journal = {Orthopaedic Surgery},
  year = {2024},
  volume = {16},
  number = {11},
  pages = {2732--2740},
  doi = {10.1111/os.14196}
}