Safety and Effectiveness of Robotic‐Arm Assisted Total Knee Arthroplasty
Orthopaedic Surgery · 2024-04 · 16 (4) · 882-893
DOI: 10.1111/os.14008 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Orthopaedic Surgery, online erschienen am 26.02.2024. Verfasst von Mingcheng Yuan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, West China Hospital of Sichuan University/West China School of Medicine, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 1.3.5 project for disciplines of excellence, West China Hospital, Sichuan University, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objective
We investigated the advantages of robotic arm‐assisted total knee arthroplasty (raTKA) over conventional manual TKA (cmTKA) by comprehensively comparing patients who received raTKA and cmTKA in terms of postoperative pain, function, imaging assessment, and trauma to the body. This study investigated the efficacy and safety of raTKA in patients using the YUANHUA‐TKA system.
Methods
In a prospective, randomized single‐blind trial, 60 patients undergoing primary unilateral TKA from October 2020 to December 2020 were randomly assigned to either raTKA or cmTKA. Clinical evaluation, including the time of osteotomy and prosthesis model testing, the total operation time, the visual analogue scale at rest, VAS in motion, opioid consumption, white blood cell count, neutrophil ratio, erythrocyte sedimentation rate, C‐reactive protein (CRP), passive and active range of motion (pROM, aROM), Western Ontario and McMaster Universities Arthritis Index (WOMAC [stiffness, pain, and function]) score, gait analysis, keen society score (KSS), adverse events, and blood loss were collected by the project nurse, as well as the imaging evaluation, including the lateral tibia component angle (LTC), frontal femoral component angle, frontal tibia component angle (FTC), lateral femoral component angl, and hip–knee–ankle angle (HKA). The student t ‐test (or the Wilcoxon signed‐rank test) and the χ 2 ‐test (or the Fisher exact test) were used to determine differences in categorical variables.
Results
No significant difference was found between the two groups in pain throughout the whole follow‐up period. On the third day postoperatively, the erythrocyte sedimentation rate in the cmTKA group was significantly higher ( p = 0.02), as well as the CRP ( p = 0.04). No significant difference was found in the WOMAC stiffnes score or pROM. However, the aROM and the flexion range when walking (FRW) were significantly better in the raTKA group throughout the trial ( p < 0.05). The KSS at the 1‐month follow‐up and the WOMAC function score at the 1‐year follow‐up were both significantly better in the raTKA group ( p < 0.05). The HKA and the LTC in the raTKA group closer to the ideal angle, and the difference between the groups was significant ( p < 0.05). The total operation time of the raTKA group was significantly longer ( p = 0.001). The intraoperative blood loss had no significant difference in the two groups.
Conclusion
Compared with cmTKA, raTKA with the YUANHUA robot not only avoids extra pain and trauma in patients but promises better functional recovery and improves the accuracy of the prosthesis position and axial alignment reconstruction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, West China Hospital of Sichuan University/West China School of Medicine, Sichuan University, Chengdu, China.
ORCID-Profile: Mingcheng Yuan
Förderung
- 1.3.5 project for disciplines of excellence, West China Hospital, Sichuan University
- National Natural Science Foundation of China
Zitieren
APA
Yuan, M., Ling, T., Su, Q., Wan, X., Lai, Y., & Zhou, Z. (2024). Safety and Effectiveness of Robotic‐Arm Assisted Total Knee Arthroplasty. Orthopaedic Surgery, 16(4), 882-893. https://doi.org/10.1111/os.14008
Vancouver
Yuan M, Ling T, Su Q, Wan X, Lai Y, Zhou Z. Safety and Effectiveness of Robotic‐Arm Assisted Total Knee Arthroplasty. Orthopaedic Surgery. 2024;16(4):882-893. doi:10.1111/os.14008
BibTeX
@article{Yuan2024,
author = {Yuan, Mingcheng and Ling, Tingxian and Su, Qiang and Wan, Xufeng and Lai, Yahao and Zhou, Zongke},
title = {Safety and Effectiveness of Robotic‐Arm Assisted Total Knee Arthroplasty},
journal = {Orthopaedic Surgery},
year = {2024},
volume = {16},
number = {4},
pages = {882--893},
doi = {10.1111/os.14008}
}
EUVIMED