EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Operative Effect Comparison of Flexible Drill Guiding vs. Traditional Drill Guiding Template for Lower Cervical Pedicle Screw Insertion: A Retrospective Analysis

Chao Wu iD, Jiayan Deng, Haigang Hu, Danwei Shen, Binwei Qin, Xiangyu Wang, Tao Gao, Lian Xu

Orthopaedic Surgery · 2023

DOI: 10.1111/os.13773 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Surgery, 2023. Verfasst von Chao Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China. Hauptthemen laut MEDLINE: Pedicle Screws, Surgery, Computer-Assisted, Surgical Wound, Spinal Fusion. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Project of Zigong Science and Technology, Sichuan Medical Association Research Project, Sichuan University-Zigong City Science and Technology Cooperation Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Accurately inserting pedicle screws is the key point of posterior pedicle screw fixation for lower cervical spine (C3–C7) instability. 3D printing technology can improve the accuracy of screw placement. This study compared the safety of 3D‐printed flexible drill guiding template vs. traditional rigid drill guiding template for lower cervical pedicle screw insertion.

Methods

This was a retrospective study. A total of 34 patients who underwent lower cervical pedicle screw fixation from March 2018 to May 2021 were enrolled in this study, and they were divided into the flexible drill flexible drill group and the traditional drill group. A total of 18 patients in the flexible drill flexible drill group underwent pedicle screw fixation assisted by 3D printed flexible drill guiding templates for the lower cervix, and 16 patients in the traditional drill group underwent pedicle screw fixation assisted by 3D printed regular drill guiding templates for the lower cervix. The length of the incision and intraoperative blood loss during surgery were recorded and compared for the two groups. The grade, deviation of the screw entry point, deviation of the screw medial angle and screw length were measured and compared after surgery for the two groups by independent‐sample tests.

Results

There was a significant difference in the length of the incision and blood loss between the two groups ( P < 0.05). There was a significant difference between the two groups for grade ( P = 0.016). The deviation of the screw entry point was 0.65 ± 0.50 mm in the flexible drill group and 0.78 ± 0.83 mm in the traditional drill group. The deviation of the screw medial angle was 2.14 ± 1.78 in the flexible drill group and 4.23 ± 2.51 in the traditional drill group, with a significant difference between the two groups ( P < 0.05).

Conclusion

Compared with regular guiding techniques, lower cervical pedicle screw placement assisted by multistep navigation templates and flexible K‐wires results in less trauma and better safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pedicle ScrewsSurgery, Computer-AssistedSurgical WoundSpinal FusionFemaleHumansRetrospective StudiesCervix UteriCervical VertebraePrinting, Three-Dimensional

Stichwörter der Autor:innen

3D PrintGuiding templateLower cervicalPedicle screw

Autor:innen und Institutionen

  • Department of Orthopaedics, Zigong Fourth People's Hospital, Zigong, China.
  • Institute of Digital Medicine, Zigong Academy of Big Data for Medical Science and Artificial Intelligence, Zigong, China.
  • Department of Orthopaedics, Hospital of Southwest Medical University, Luzhou, China.

ORCID-Profile: Chao Wu

Förderung

  • Key Project of Zigong Science and Technology
  • Sichuan Medical Association Research Project
  • Sichuan University-Zigong City Science and Technology Cooperation Project

Zitieren

APA

Wu, C., Deng, J., Hu, H., Shen, D., Qin, B., Wang, X., Gao, T., & Xu, L. (2023). Operative Effect Comparison of Flexible Drill Guiding vs. Traditional Drill Guiding Template for Lower Cervical Pedicle Screw Insertion: A Retrospective Analysis. Orthopaedic Surgery. https://doi.org/10.1111/os.13773

Vancouver

Wu C, Deng J, Hu H, Shen D, Qin B, Wang X, et al. Operative Effect Comparison of Flexible Drill Guiding vs. Traditional Drill Guiding Template for Lower Cervical Pedicle Screw Insertion: A Retrospective Analysis. Orthopaedic Surgery. 2023. doi:10.1111/os.13773

BibTeX
@article{Wu2023,
  author = {Wu, Chao and Deng, Jiayan and Hu, Haigang and Shen, Danwei and Qin, Binwei and Wang, Xiangyu and Gao, Tao and Xu, Lian},
  title = {Operative Effect Comparison of Flexible Drill Guiding vs. Traditional Drill Guiding Template for Lower Cervical Pedicle Screw Insertion: A Retrospective Analysis},
  journal = {Orthopaedic Surgery},
  year = {2023},
  doi = {10.1111/os.13773}
}
Kostenlos starten →