Journal article in Orthopaedic Surgery, 2023. Written by Yi Long and 8 co-authors. Institution: Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China. Major MEDLINE topics: Shoulder Joint, Rotator Cuff Injuries. Cited 6 times so far (Crossref); 43 references. The full text is freely available (open access, CC BY 4.0). Funded by: Fundamental Research Funds for the Central Universities, Sun Yat-sen University, National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (original language)
Objective
Anteroposterior (AP) radiographs do not necessarily offer the optimal approach to measuring the critical shoulder angle (CSA) due to the malposition of the scapula. Three‐dimensional computed tomography (3D‐CT) may offer some advantages, including the ability to rotate the scapula for position alignment and pre‐operative planning for reducing CSA. This study aimed to investigate the accuracy and reliability of CSA measurement in 3D‐CT and to determine whether there is an association between CSA and rotator cuff tears (RCTs).
Methods
In this retrospective study we identified 200 patients who received shoulder arthroscopy from 2019 to 2021, including 142 patients (81 females, 61 males) with RCTs and 58 patients (14 females, 44 males) with non‐RCTs. For each participant, CSA was measured from standard shoulder AP radiographs and anterior views of 3D‐CT of the scapula by two independent assessors. Inter‐ and intra‐observer agreements were assessed by the intraclass correlation coefficient (ICC). The relationship between the two measurement methodologies was determined by Spearman's correlation coefficient and Bland–Altman plots. Discriminative capacity was calculated by using receiver operating curve (ROC) analyses in the whole cohort and age sub‐groups above and below 45 years.
Results
We found perfect inter‐observer (ICC >0.96) and intra‐observer (ICC >0.97) reliabilities for CSA measurements obtained from the standard AP radiographs and the 3D‐CT. There was a strong correlation between the two methods ( r = 0.960, P < 0.001). The mean CSA was 31.7° ± 4.2° in the standard AP radiographs and 31.8° ± 4.4° in the 3D‐CT (mean difference 0.02°, P = 0.940; bias 0.02°, limits of agreement −2.29° to +2.33°). ROC analysis of the whole cohort showed that the CSA measured in the standard AP radiographs (area under the ROC curve [AUC] = 0.812, P < 0.001) and the 3D‐CT (AUC = 0.815, P < 0.001) predicted RCT with high confidence. ROC analysis of patients aged ≥45 years showed that the CSA measured from the standard AP radiographs (AUC = 0.869, P < 0.001) and the 3D‐CT (AUC = 0.870, P < 0.001) were very good at predicting RCTs.
Conclusion
CSA measured from standard AP radiographs and 3D‐CT showed high consistency, and the CSA could be accurately and reliably measured using 3D‐CT. CSAs measured from standard AP radiographs and 3D‐CT could predict RCTs, especially in patients aged ≥45 years.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Orthopaedics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
- Department of Radiology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
ORCID profiles: Yi Long, Chuanhai Zhou, Min Zhou, Rui Yang
Funding
- Fundamental Research Funds for the Central Universities, Sun Yat-sen University
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
Cite
APA
Long, Y., Hu, H., Zhou, C., Hou, J., Wang, Z., Zhou, M., Cui, D., Xu, X., & Yang, R. (2023). The Critical Shoulder Angle Can be Accurately and Reliably Determined from Three‐Dimensional Computed Tomography Images. Orthopaedic Surgery. https://doi.org/10.1111/os.13652
Vancouver
Long Y, Hu H, Zhou C, Hou J, Wang Z, Zhou M, et al. The Critical Shoulder Angle Can be Accurately and Reliably Determined from Three‐Dimensional Computed Tomography Images. Orthopaedic Surgery. 2023. doi:10.1111/os.13652
BibTeX
@article{Long2023,
author = {Long, Yi and Hu, Huijun and Zhou, Chuanhai and Hou, Jingyi and Wang, Zhiling and Zhou, Min and Cui, Dedong and Xu, Xiaoding and Yang, Rui},
title = {The Critical Shoulder Angle Can be Accurately and Reliably Determined from Three‐Dimensional Computed Tomography Images},
journal = {Orthopaedic Surgery},
year = {2023},
doi = {10.1111/os.13652}
}
EUVIMED