EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study

Zhihua Han iD, Qian Luo, Guoying Deng, Chun Bi, Gang Yin, Haodong Lin iD, Jianhong Wu, Xiaoming Wu

Orthopaedic Surgery · 2023-08 · 15 (8) · 2152-2156

DOI: 10.1111/os.13558 ↗

At a glance

Journal article in Orthopaedic Surgery, published online on 2022-11-09. Written by Zhihua Han and 7 co-authors. Institution: Trauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China. Major MEDLINE topics: Clavicle, Fractures, Bone. Cited 6 times so far (Crossref); 24 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

Implant failure is a disastrous complication of the operative treatment of midshaft clavicle fractures, and improving the osteosynthesis plate is a strategy for preventing this. We aimed to investigate whether canceling the notch and adding screw‐hole inserts enhanced the mechanical properties of the plate.

Methods

A clavicle model was generated based on the CT images of six adult volunteers (age range, 20–40 years; three males and three females; height range 160–175) using dedicated software, and a midshaft fracture model was created. The domestically made seven‐hole locking plate commonly used for midshaft clavicle fractures was simulated (Model I); modifications were made to the plate (Model II). Using 3D finite element analysis, we simulated the fracture construct under three different load conditions—downward cantilever bending, axial compression, and axial torsion—and compared the stress distribution.

Results

We found that under axial compression, Model II experienced its maximum stress on the plate at 551.9MPa, which was less than that in Model I (790.4 MPa). Moreover, a greater stress concentration at the fracture site was observed under axial torsion, despite the maximum stress of both the models being similar.

Conclusion

Canceling the notch and filling the screw holes near the fracture can ameliorate stress concentration on the internal fixation construct and enhance its reliability under axial compression. This improvement has substantial effects on the mechanical properties of implants and potentially prevents implant failure. Modern osteosynthesis anatomical implants need to be improved.

Subjects

MeSH terms (MEDLINE)

ClavicleFractures, BoneMaleFemaleHumansYoung AdultAdultFinite Element AnalysisReproducibility of ResultsBiomechanical PhenomenaFracture Fixation, InternalBone Plates

Author keywords

BiomechanicsClavicle fractureFinite elementLocking plate

Authors and institutions

  • Trauma Center, Department of Orthopaedics and Traumatology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.
  • Sino-Euro Orthopaedics Network, Berlin, Germany.
  • Department of Radiology, Shanghai General Hospital, Shanghai Jiaotong University, Shanghai, China.

ORCID profiles: Zhihua Han, Haodong Lin

Cite

APA

Han, Z., Luo, Q., Deng, G., Bi, C., Yin, G., Lin, H., Wu, J., & Wu, X. (2023). Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study. Orthopaedic Surgery, 15(8), 2152-2156. https://doi.org/10.1111/os.13558

Vancouver

Han Z, Luo Q, Deng G, Bi C, Yin G, Lin H, et al. Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study. Orthopaedic Surgery. 2023;15(8):2152-2156. doi:10.1111/os.13558

BibTeX
@article{Han2023,
  author = {Han, Zhihua and Luo, Qian and Deng, Guoying and Bi, Chun and Yin, Gang and Lin, Haodong and Wu, Jianhong and Wu, Xiaoming},
  title = {Canceling Notch Improves the Mechanical Safety of Clavicle Locking Plate: A 3D Finite Element Study},
  journal = {Orthopaedic Surgery},
  year = {2023},
  volume = {15},
  number = {8},
  pages = {2152--2156},
  doi = {10.1111/os.13558}
}