Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Javier Rojas Viñuela und 4 weiteren Autor:innen. Beteiligte Einrichtung: Natural Optics Balaguer, Lleida, Spain. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Sclera, Cornea, Prosthesis Fitting. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To analyse the associations between ocular surface shape parameters and soft contact lens fitting.
Methods
A total of 106 eyes of 53 participants (53 right and 53 left eyes) fitted with standard silicone hydrogel soft lenses were analysed retrospectively. The sagittal height of the lenses was obtained from an independent publication. The lens fit was analysed objectively with proprietary software and corneo‐scleral parameters were obtained with the Eye Surface Profiler. The relationship between the sagittal height of the eye (OC‐SAG) and the lens (CL‐SAG) was defined as the delta‐sag (δ‐sag) and characterised for this group.
Results
The OC‐SAG and δ‐sag were in the range of 3600 and 400 μm, respectively, with no statistically significant differences between the right and left eyes. There were statistically significant differences between the corneoscleral junction (CSJ) angle of the right and left eyes ( p = 0.002). The nasal portion showed the sharpest transition in both eyes and was significantly different between the right and left eyes only in that specific quadrant ( p < 0.001). The peripheral cornea (α) was steeper with a mean value around 38°. The proximal sclera (β) showed a flatter slope close to 36° in both eyes. Following the pattern of the CSJ angle, there were statistically significant differences only between the nasal‐α of the right and left eyes ( p < 0.001). There were no significant correlations between the δ‐sag and the lens fitting features in either eye ( p > 0.05). Some moderate and strong associations between the lens fit and peripheral ocular parameters were found, although they were not consistent between the right and left eyes.
Conclusion
Soft contact lens movement seems to be influenced by the corneo‐scleral transition at the superior and inferior quadrants. It would be better to focus on the slopes in these peripheral areas rather than the central corneal parameters or the sagittal height.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Natural Optics Balaguer, Lleida, Spain.
- School of Optometry, Aston University, Birmingham, UK.
- Aragon Institute for Engineering Research, University of Zaragoza, Zaragoza, Spain.
- Eye-Contact-Lens Research and Education, Amsterdam, the Netherlands.
- Department of Optics, Pharmacology, and Anatomy, University of Alicante, Alicante, Spain.
- Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain.
ORCID-Profile: James S Wolffsohn, Alejandra Consejo, David P Piñero
Zitieren
APA
Viñuela, J. R., Wolffsohn, J. S., Consejo, A., van der Worp, E., & Piñero, D. P. (2025). Ocular surface characteristics and its association with soft contact lens fitting. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13559
Vancouver
Viñuela JR, Wolffsohn JS, Consejo A, van der Worp E, Piñero DP. Ocular surface characteristics and its association with soft contact lens fitting. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13559
BibTeX
@article{Viuela2025,
author = {Viñuela, Javier Rojas and Wolffsohn, James S and Consejo, Alejandra and van der Worp, Eef and Piñero, David P},
title = {Ocular surface characteristics and its association with soft contact lens fitting},
journal = {Ophthalmic and Physiological Optics},
year = {2025},
doi = {10.1111/opo.13559}
}
EUVIMED