Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2023. Verfasst von Alejandra Consejo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Physics, University of Zaragoza, Zaragoza, Spain. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Sclera, Corneal Topography, Cornea. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Cátedra SAMCA de Desarrollo Tecnológico de Aragón, Universidad de Zaragoza, MCIN/AEI/10.13039/501100011033, MCIN/AEI/10.13039/501100011033 and European Union "NextGenerationEU"/PRTR.
Abstract (Originalsprache)
Purpose
To objectively quantify changes in corneoscleral profile, as evaluated by the limbus position and corneoscleral junction (CSJ) angle, as a consequence of wearing different soft contact lens (CL) materials.
Methods
Twenty‐two healthy participants wore silicone hydrogel (SiHy, MyDay, CooperVision) and hydrogel (Hy, Biomedics 1 day extra, CooperVision) soft CLs for 8 h per lens in their left eye. In each session, corneoscleral topography was captured before and immediately after CL removal with an Eye Surface Profiler. Previously validated automatic and objective algorithms for limbal position and CSJ angle calculation were applied to 360 semi‐meridians to investigate the effect of short‐term CL wear on corneoscleral topography, globally and by sectors, depending on the soft CL material worn.
Results
Short‐term soft CL wear significantly impacted limbal position (SiHy: 120 ± 97 μm, Hy: 128 ± 85 μm) and CSJ angle (SiHy: 0.57 ± 0.36°, Hy: 0.55 ± 0.40°); all p < 0.05. A statistically significant difference was found between the sectors with regard to limbus position and CSJ angle before CL wear that remained following lens wear (all pairwise comparisons, p < 0.001). Although individual differences were observed, there was no evidence that one material caused more substantial corneoscleral alterations.
Conclusion
Corneoscleral profile parameters were altered significantly following 8 h of soft CL wear. The observed changes in limbus position and CSJ angle support the importance of participant‐material biocompatibility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Applied Physics, University of Zaragoza, Zaragoza, Spain.
- Aragon Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain.
ORCID-Profile: Alejandra Consejo, Laura Remon
Förderung
- Cátedra SAMCA de Desarrollo Tecnológico de Aragón, Universidad de Zaragoza
- MCIN/AEI/10.13039/501100011033
- MCIN/AEI/10.13039/501100011033 and European Union "NextGenerationEU"/PRTR
Zitieren
APA
Consejo, A., Roll, V., Roman, D. M., & Remon, L. (2023). The influence of soft contact lens material on the corneoscleral profile. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13193
Vancouver
Consejo A, Roll V, Roman DM, Remon L. The influence of soft contact lens material on the corneoscleral profile. Ophthalmic and Physiological Optics. 2023. doi:10.1111/opo.13193
BibTeX
@article{Consejo2023,
author = {Consejo, Alejandra and Roll, Vanesa and Roman, Denisa M and Remon, Laura},
title = {The influence of soft contact lens material on the corneoscleral profile},
journal = {Ophthalmic and Physiological Optics},
year = {2023},
doi = {10.1111/opo.13193}
}
EUVIMED